Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From January 4, 2012 to February 2, 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was performed according to the OECD 209 Guideline with GLP.
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
yes
Details on sampling:
- Concentrations: 10, 32 100, 320 and 1000mg/L
- Sampling method: The synthetic sewage feed (16 mL) and an adequate amount of the test substance loading were mixed and made up to 250 mL with Milli-RO water in a 1 litre bottle. The pH was determined. Thereafter 250 mL activated sludge was added. This was the start of the test. The mixture was then aerated during the contact time, using a pipette as an aeration device.
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: 1-Litre test bottles were filled with 200 mL of test substance mixtures in Milli-RO water (tap water purified by reverse osmosis; Millipore Corp., Bedford, Mass., USA) with initial loading rates of 2.5 times the final loading rate.
- Eluate: Milli-RO wate
- Controls: Blank Control, Nitrification control and Abiotic control of test substance.
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Laboratory culture: Municipal sewage treatment plant: 'Waterschap Aa en Maas', 's-Hertogenbosch, The Netherlands, receiving predominantly domestic sewage.
- Preparation of inoculum for exposure: The batch of sludge was used one day after collection; therefore 50 mL of synthetic sewage feed was added per litre of activated sludge at the end of the collection day. The sludge was kept aerated at test temperature until use.
- Pretreatment: The sludge was coarsely sieved, washed and diluted with ISO-medium. A small amount of the sludge was weighed and dried overnight at ca. 105°C to determine the amount of suspended solids (3.0 g/L of sludge, as used for the test). The pH was 7.7 on the day of testing.
- Initial biomass concentration: 3.0 g/L of sludge
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Post exposure observation period:
approximately 10 minutes.
Test temperature:
18.0 - 19.9 ºC
pH:
6.9 - 8.0
Details on test conditions:
TEST SYSTEM
- Test vessel: All glass bottles/vessels.
- Type (delete if not applicable): closed
- Material, size, headspace, fill volume: 1 litre
- Aeration: The aeration was adjusted in such a way that the dissolved oxygen concentration at the start was above 60-70% saturation (60% of air saturation is > 5 mg/L at 20°C) and to maintain the sludge flocs in suspension.
- No. of vessels per concentration (replicates): 5
- No. of vessels per control (replicates): 6
- Biomass loading rate: Initial amount of suspended solids 3.0 g/L of sludge, 1.5 g/L in the final text mixture.

TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: Adjusted ISO medium, formulated using RO-water (tapwater purified by reverse osmosis; GEON Waterbehandeling, Berkel-Enschot, The Netherlands)


EFFECT PARAMETERS MEASURED (with observation intervals if applicable): the oxygen consumption was recorded for a period of approximately 10 minutes

TEST CONCENTRATIONS
- Range finding study: combined limit/range-finding test
- Test concentrations: 10, 32, 100, 320 and 1000 mg/L
- Results used to determine the conditions for the definitive study: There was no oxygen uptake from abiotic processes and the results at 1000 mg/L with a nitrification inhibitor showed that the heterotrophic inhibition of the respiration rate was slightly higher than the total inhibition. N-allylthiourea was not used in the final test.
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
100 mg/L
Conc. based on:
test mat.
Duration:
3 h
Dose descriptor:
EC10
Effect conc.:
310 mg/L
Conc. based on:
test mat.
Duration:
3 h
Dose descriptor:
other: EC20
Effect conc.:
> 1 000 mg/L
Conc. based on:
test mat.
Results with reference substance (positive control):
- Results with reference substance valid? yes
Reported statistics and error estimates:
No statistically significant test substance related inhibition of the respiration rate of the sludge was recorded at or below a loading rate of 100 mg Reaction products of n-octanol and acrylic acid, first distillation pitch / litre (Bonferroni t-Test: α=0.05 Toxstat).

Table 1. Final test - Summarized overview of the study results.

Flask

Loading rate

(mg/L)

Temp

(°C)

pH before addition

of sludge

pH after

3 h contact time

Oxygen conc. at the start

(~ mg O2/L)

Respiration

rate

(mg O2/L h)

Respiration

rate

(mg O2/g h)1

%

Inhibition respiration relative to the control (mean value)

Control

0

19.3­19.9

7.5

7.9

7.6-8.8

49

32

-

T 1

10

18.0­19.1

7.4-7.5

7.8-8.0

6.8-8.9

41

28

15*2

T 2

32

19.5­19.7

7.4

7.7-7.8

7.0-9.0

50

33

-2

T 3

100

18.0­19.5

7.3-7.4

7.8-7.9

6.8-8.3

45

30

6

T 4

320

18.0­18.7

7.2

7.8-7.9

6.9-8.7

43

28

12*

T 5

1000

18.0­19.5

6.9-7.0

7.7-7.8

7.4-8.8

42

28

14*

1The amount of suspended solids in the final test mixture was 1.5 g/L.

*Statistically significant (Bonferroni t-Test: a=0.05 Toxstat).

2This response was not test substance loading rate related and therefore considered as not significant for the test.

Table 2. Effect parameters for the inhibition of the respiration rate.

 

Reaction products of n-octanol and acrylic acid, first  

distillation pitch

Parameter

 Loading rate (mg/L)

NOEC

100

EC10

310

EC20,50,80

>1000

Table 3. Combined limit/range-finding Test – Study results.

 

Flask

Conc./ loading rate

(mg/L)

Temp

(°C)

pH

before addition

of

sludge

pH after

3 h contact time

Oxygen conc. at the start

(~ mg O2/L)

Respiration

rate

(mg O2/L h)

Respiration rate

(mg O2/g h)1

% Inhibition respiration relative to the control

(mean value)

C 1

0

20.7

7.6

7.7

8.4

61

41

 

C 2

0

19.4

7.5

7.5

8.8

49

33

 

Mean

 

 

 

 

 

55

37

 

SD

 

 

 

 

 

8

6

 

CV

(%)

 

 

 

 

 

15

15

 

 

 

 

 

 

 

 

 

 

CN

0

20.8

7.5

8.2

8.6

36

24

35

 

 

 

 

 

 

 

 

 

R 1

5.0

19.4

7.5

8.1

8.4

30

20

45

R 2

12

20.0

7.5

8.0

8.6

16

11

71

R 3

30

20.0

7.5

8.1

8.9

6

4

89

 

 

 

 

 

 

 

 

 

T1

10

20.7

7.5

7.4

8.8

59

39

-7

T2

100

21.8

7.5

7.2

8.6

53

35

4

T3a

1000

20.0

7.4

7.2

8.3

43

29

22

T3b

1000

20.3

7.4

7.1

8.5

43

29

22

T3c

1000

20.1

7.4

7.1

8.6

41

27

25

T3 mean

 

 

 

 

 

42

28

23

 

 

 

 

 

 

 

 

 

TA

1000

19.7

6.9

6.8

8.8

1

1

98

TN

1000

19.1

7.4

7.6

6.7

22

15

392

C:

Blank Control

CN:

Nitrification control

R:

Reference substance, 3,5-dichlorophenol

T:

Test substance, Reaction products of n-octanol and acrylic acid, first distillation pitch

CV:

Coefficient of variation

ATU

N-allylthiourea

TA:

Abiotic control of test substance.

TN:

Test substance with ATU.

1

The amount of suspended solids in the final test mixture was 1.5 g/L.

2

Relative to CN

Table 4. Final Test – Study results.

 

Flask

Conc./ loading rate

(mg/L)

Temp (°C)

pH

before addition

of

sludge

pH after

3 h contact time

Oxygen conc. at the start (~ mg O2/L)

Respiration

rate (mg O2/L h)

Respiration rate

(mg O2/g h)1

%

Inhibition respiration relative to the control (mean value)

C 1

0

19.4

7.5

7.9

7.6

42

28

 

C 2

0

19.9

7.5

7.9

8.1

50

33

 

C 3

0

19.4

7.5

7.9

7.7

48

32

 

C 4

0

19.9

7.5

7.9

7.7

52

35

 

C 5

0

19.6

7.5

7.9

8.8

50

33

 

C 6

0

19.3

7.5

7.9

8.3

49

33

 

Mean

 

 

 

 

 

49

32

 

SD

 

 

 

 

 

3

2

 

CV

(%)

 

 

 

 

 

7

7

 

 

 

 

 

 

 

 

 

 

R 1

5.0

19.0

7.5

8.1

7.1

23

15

53

R 2

12

19.3

7.5

8.1

7.5

14

9

71

R 3

30

19.2

7.5

8.2

8.1

7

5

86

 

 

 

 

 

 

 

 

 

T 1a

10

19.1

7.5

7.9

8.2

44

29

9 *2

T 1b

10

18.7

7.5

7.9

7.8

41

27

15 *2

T 1c

10

19.0

7.4

7.8

6.8

44

29

9 *2

T 1d

10

18.0

7.4

7.9

8.9

41

27

15 *2

T 1e

10

18.1

7.4

8.0

8.6

37

25

24 *2

 

 

 

 

 

 

 

 

 

T 2a

32

19.7

7.4

7.8

8.2

51

34

-5

T 2b

32

19.7

7.4

7.8

7.9

50

33

-3

T 2c

32

19.5

7.4

7.8

7.0

49

33

-1

T 2d

32

19.5

7.4

7.8

8.8

49

33

-1

T 2e

32

19.6

7.4

7.7

9.0

49

33

-1

 

 

 

 

 

 

 

 

 

T 3a

100

18.4

7.4

7.9

8.0

42

28

13

T 3b

100

18.0

7.4

7.9

7.6

43

29

11

T 3c

100

19.2

7.4

7.8

6.8

51

34

-5

T 3d

100

19.5

7.3

7.8

8.3

48

32

1

T 3e

100

18.2

7.4

7.9

8.0

43

29

11

 

 

 

 

 

 

 

 

 

T 4a

320

18.3

7.2

7.9

8.4

41

27

15 *

T 4b

320

18.0

7.2

7.8

8.2

39

26

20 *

T 4c

320

18.3

7.2

7.8

6.9

46

31

5 *

T 4d

320

18.0

7.2

7.9

8.2

40

27

18 *

T 4e

320

18.7

7.2

7.8

8.7

47

31

3 *

 

 

 

 

 

 

 

 

 

T 5a

1000

19.5

7.0

7.7

8.4

45

30

7 *

T 5b

1000

19.4

7.0

7.7

8.4

44

29

9 *

T 5c

1000

18.0

7.0

7.8

7.4

35

23

28 *

T 5d

1000

18.4

7.0

7.8

8.8

41

27

15 *

T 5e

1000

18.7

6.9

7.7

8.4

44

29

9 *

C: Control

R: Reference substance, 3,5-dichlorophenol

T: test substance, Reaction products of n-octanol and acrylic acid, first distillation pitch

CV: Coefficient of variation

1 The amount of suspended solids in the final test mixture was 1.5 g/L.

* Statistically significant (Bonferroni t-Test: a=0.05 Toxstat)

2 This response was not test substance loading rate related and therefore considered as not significant for the test.

Validity criteria fulfilled:
yes
Conclusions:
The test substance was not toxic to waste water (activated sludge) bacteria at or below a loading rate of 100 mg/L (NOEC).
Executive summary:

The activated sludge respiration inhibition test with Reaction products of n-octanol and acrylic acid, first distillation pitch was determinated according to the OECD 209 test guideline and with GLP. The final test was performed based on the result of a preceding combined limit/range-finding test. Five loading rates, ranging from 10 to 1000 mg/L, increasing with a factor 3.2 were tested. Five replicates per loading rate and six replicates for an untreated control group were tested. No statistically significant test substance related inhibition of the respiration rate of the sludge was recorded at or below a loading rate of 100 mg Reaction products of n-octanol and acrylic acid, first distillation pitch / litre. At a loading rate of 320 and 1000 mg/L the inhibition of the respiration rate on aerobic waste water (activated sludge) bacteria was 12 and 14%, respectively. The EC10 value was 310 mg/L and the EC20,50,80 was > 1000 mg/L.

Description of key information

Key study: OECD Guideline 209. GLP study. The test substance was determined to be not toxic to waste water (activated sludge) bacteria at or below a loading rate of 100 mg/L (NOEC).

Key value for chemical safety assessment

EC50 for microorganisms:
1 000 mg/L
EC10 or NOEC for microorganisms:
100 mg/L

Additional information

Key study: Experimental result on test item Reaction products of n-octanol and acrylic acid, first distillation pitch:

The influence of the test substance on the respiration rate of activated sludge was investigated after a contact time of 3 hours according to the OECD 209 Guideline (GLP study). The test substance was determined to be not toxic to waste water (activated sludge) bacteria at or below a loading rate of 100 mg/L (NOEC). The EC10 was at a loading rate of 310 mg/L. The EC20,50,80 were above the highest loading rate of 1000 mg/L.