Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin sensitisation: in vivo (LLNA)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study according to guideline, limited documentation

Data source

Reference
Reference Type:
publication
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 429 (Skin Sensitisation: Local Lymph Node Assay)
Deviations:
no
GLP compliance:
not specified
Type of study:
mouse local lymph node assay (LLNA)

Test material

Constituent 1
Chemical structure
Reference substance name:
Cyclohexanone oxime
EC Number:
202-874-0
EC Name:
Cyclohexanone oxime
Cas Number:
100-64-1
Molecular formula:
C6H11NO
IUPAC Name:
cyclohexanone oxime
Test material form:
not specified
Details on test material:
- Name of test material (as cited in study report): cyclohexanone oxime
- Analytical purity: not stated, but puritiy 97% acc. to information on supplier's website (Jan 2013)

In vivo test system

Test animals

Species:
mouse
Strain:
CBA
Sex:
female
Details on test animals and environmental conditions:
TEST ANIMALS
- Source: Harlan (Horst, The Netherlands) or Scanbur (Sollentuna, Sveden)
- Age at study initiation: 8 weeks

Study design: in vivo (LLNA)

Vehicle:
acetone/olive oil (4:1 v/v)
Concentration:
0, 0.1, 1, 5, 10 or 20%
No. of animals per dose:
3-4
Details on study design:
- Quantitative criteria used to consider a positive response: EC3 < 0.1 extreme; >=0.1-<1: strong; >=1-<10 moderate;>=10-100: weak

TREATMENT PREPARATION AND ADMINISTRATION:
Mice received 25 μL of the test compound dissolved in vehicle on the dorsum of the ears daily for three consecutive days. Control animals were treated in the same way with vehicle. Mice were injected intravenously five days after the first treatment with 20 μCi of [3H]thymidine in 250 μL of phosphate-buffered saline. Five hours later, draining auricular lymph nodes were excised and pooled for each group. A single cell suspension of lymph node cells was prepared. The thymidine incorporation was measured by scintillation counting.
Results are expressed as mean dpm/lymph node for each experimental group and as stimulation index (SI), that is, test group/control group ratio.
Positive control substance(s):
not specified
Statistics:
EC3 values (concentration required to induce a stimulation index (SI) of 3) were calculated with linear interpolation

Results and discussion

Positive control results:
Other test substances produced SI up to 11.3 can therefore be considered as valid positive controls

In vivo (LLNA)

Resultsopen allclose all
Parameter:
SI
Remarks on result:
other: Conc. SI [% w/v) Control: - 0.1: 0.96 1: 0.90 5: 0.77 10: 1.17 20 0.84
Parameter:
other: disintegrations per minute (DPM)
Remarks on result:
other: Conc. dpm [% w/v) Control: 1081 0.1: 1036 1: 978 5: 828 10: 1260 20 906

Applicant's summary and conclusion

Interpretation of results:
not sensitising
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
Under the conditions of this study the test substance was not sensitising
Executive summary:

Female mice (3-4 per dose group) received the test item on the dorsum of the ears daily for three consecutive days in concentrations of 0, 0.1, 1, 5, 10 or 20% in acetone/olive oil (4:1) vehicle. Five days later the animals were injected i.v. with 20 µCi 3H-thymidine in 250 µL phosphate buffered saline. The auricular lymph nodes were excised 5 h later and pooled from each group. The prepared cell suspension (one per dose group) was measured by scintillation counting. Dpm/lymph nodes were determined and the stimulation index (SI) compared to controls as well as the effect concentration producing a 3 -fold increase in SI (EC3) were calculated. The test substance produced SI between 0.77 and 1.17, resulting in an EC3 > 20%. According to the evaluation score of the authors they described the test item as weak sensitiser. Based on the guideline scoring scheme (SI >=3: positive) it is not considered to be a sensitiser. No data are given for a positive control, but other test substances produced SI up to 11.3, what is considered to be a positive response, indicating the validity of the test.

Therefore under the conditions of this study the test substance was not sensitising