Administrative data

Endpoint:
surface tension
Type of information:
other: statement
Adequacy of study:
key study
Study period:
10 September 2010 – 02 November 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
OECD and EC guidelines were followed.The water solubility of the test substance is < 0.1 mg/l (see section 4.8). According to the guidelines, substances with a water solubility < 1 mg/l need not be tested. The test on the surface tension of the test substance was therefore not performed.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
No.476 YELLOW
IUPAC Name:
No.476 YELLOW
Details on test material:
- Substance type: Yellow to orange powder (determined at NOTOX)
- Lot/batch No.: 00082

Results and discussion

Any other information on results incl. tables

The water solubility of the test substance is < 0.1 mg/l (see section 4.8). According to the guidelines, substances with a water solubility < 1 mg/l need not be tested.The test on the surface tension of the test substance was therefore not performed.

 

Applicant's summary and conclusion

Conclusions:
The water solubility of the test substance is < 0.1 mg/l (see section 4.8). According to the guidelines, substances with a water solubility < 1 mg/l need not be tested.The test on the surface tension of the test substance was therefore not performed.