Endpoint:
self-heating substances / mixtures
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is completely molten at 160°C
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 May - 05 May 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Validity criteria for the measurement of the flammability (solids): 





















Target condition according to 


guideline: 



Actual condition according to 


the study: 



Validity criteria met: 



A description of the substance to be tested, its physical state including moisture content should be stated. 



 A description of the test substance, its physical state and purity was given



 Yes



Results from the preliminary screening test and from the burning rate test if performed should be stated. 



 Result of the preliminary screening was given. The burning rate main-test was not performed



Yes 


Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item could not be ignited with a flame.
Executive summary:

In a GLP study according to EEC Method A10, a preliminary test was performed to investigate the flammability of the test substance.
The test substance could not be ignited with a flame and it melted. Therefore, the test substance is not considered to be flammable solid.

Description of key information

In a GLP study according to EEC Method A10, a preliminary test was performed to investigate the flammability of the test substance.
The test substance could not be ignited with a flame and it melted. Therefore, the test substance is not considered to be flammable solid.


The test substance is also not considered to be pyrophoric, self-heating and does not evolve flammable gases when in contact with water.

Key value for chemical safety assessment

Flammability:
not classified

Additional information