Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
10 July 2000 - 11 July 2000
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2000
Report date:
2000

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
The sample is initially observed to determine whether sieving of the material is required. The final sample is the analysed using the Coulter Laser Defraction Analyser fitted with a dry powder module. It is normal practice to complete 3 runs to ensure repeatability of results.
GLP compliance:
yes (incl. QA statement)
Type of distribution:
other: Laser diffraction analysis

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
434-770-8
EC Name:
-
Cas Number:
55314-16-4
Molecular formula:
C10 H12 N2 O1
IUPAC Name:
3-(dimethylamino)-1-(pyridin-3-yl)prop-2-en-1-one
Details on test material:
Identification: STI571 Y5A
Description: Brown solid
Batch: 0093800007
Purity: >95%
Test substance storage: In refrigerator in the dark
Stability under storage conditions: Not indicated
Expiry date: 08 May 2001

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
421.8 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
180 µm
Percentile:
D50
Mean:
421.8 µm
Percentile:
D90
Mean:
742 µm

Applicant's summary and conclusion

Conclusions:
The Particle Size Analysis produced the following results:

Volume (%): 100.0
Mean (µm): 383.8 95% Conf. Limits (µm): 122-1210
Median (µm): 421.8 S.D.: 1.79
Mode (µm): 454.6

%< 10 25 50 75 90
Size (µm) 180.0 286.0 421.8 586.3 742.0