Reference
Endpoint:
auto-flammability
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
REPORTING FORMAT FOR THE ANALOGUE APPROACH

1. HYPOTHESIS FOR THE ANALOGUE APPROACH
This read-across is based on the hypothesis that source and target substances have similar toxicological properties because
• they are manufactured from similar or identical precursors under similar conditions
• they share structural similarities with common functional groups: quaternary ammonium and saturated or unsaturated alkyl chains with comparable length (corresponding to scenario 2 of the read-across assessment framework)

The read-across hypothesis is based on structural similarity of target and source substances. Based on available experimental data, including key physicochemical properties and data from acute toxicity, irritation, sensitization (human) and genotoxicity studies, the read-across strategy is supported by a quite similar toxicological profile of all substances.

Therefore, read-across from the existing ecotoxicity, environmental fate and toxicity studies conducted with the source substances is considered as an appropriate adaptation to the standard information requirements of the REACH Regulation for the target substance, in accordance with the provisions of Annex XI, 1.5 of the REACH Regulation.

A justification for read-across is attached to IUCLID section 13.

2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
See justification for read-across attached to IUCLID section 13.

3. ANALOGUE APPROACH JUSTIFICATION
See justification for read-across attached to IUCLID section 13.

4. DATA MATRIX
See justification for read-across attached to IUCLID section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Reason / purpose for cross-reference:
read-across source
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
not specified
Auto-ignition temperature:
ca. 396 °C
Atm. press.:
993 hPa
Remarks on result:
other:
Conclusions:
The Auto-Ignition temperature measured for the substance test item was 396°C ± 5°C.

Description of key information

The Auto-Ignition temperature measured for the substance was 396°C ± 5°C. The ignition delay observed at this temperature was less than 10 seconds, and a temperature increase at the middle of the flask was 26°C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
396 °C