Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 04th, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Version / remarks:
1981
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Version / remarks:
2009
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Percentile:
D10
Mean:
6.7 µm
Remarks on result:
other: average of two measurements
Percentile:
D50
Mean:
52.1 µm
Remarks on result:
other: average of two measurements
Percentile:
D90
Mean:
178.5 µm
Remarks on result:
other: average of two measurements

Test series 1

D10: 6.7 µm

D50: 51.9 µm

D90: 178.0 µm

Test series 2

D10: 6.7 µm

D50: 52.3 µm

D90: 178.9 µm

Conclusions:
D50: 52.1 µm
Executive summary:

The particle size distribution was determined by laser diffraction measurement. The analysis has been performed according to the testing procedures described in the following guidelines: OECD 110, CIPAC MT 187 and ISO 13320. 

Conclusion

The median particle size D50 of the test item resulted to be 52.1 µm

Description of key information

D50: 52.1 µm

Additional information

OECD 110, CIPAC MT 187, ISO 13320 - laser diffraction measurement