Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: ISO 13320:2009 Particle size analysis by Laser diffraction
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Hydroxylapatite (Ca5(OH)(PO4)3)
EC Number:
215-145-7
EC Name:
Hydroxylapatite (Ca5(OH)(PO4)3)
Cas Number:
1306-06-5
Molecular formula:
Ca5HO13P3
IUPAC Name:
pentacalcium hydroxide triphosphate
Test material form:
solid: particulate/powder

Results and discussion

Mass median aerodynamic diameter:
7.6 µm
Particle sizeopen allclose all
Key result
Percentile:
other: MMAD
Mean:
7.6 µm
Remarks on result:
other: no "St.dev" is given
Key result
Percentile:
D50
Mean:
4.3 µm
Remarks on result:
other: no "St.dev" is given

Applicant's summary and conclusion

Conclusions:
Test item shows a particle size distribution of D50 = 4.3 µm.
The mass median aerodynamic diameter (MMAD) of the test item is calculated as ca. 7.6 µm
(based on relative density = 3.16 and shape factor K=1 for spheric particles)