Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report date:
2002

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
Deviations:
not specified
GLP compliance:
no
Remarks:
(study performed according to SOP in a laboratory that conforms to GLP but report not audited by the QAU)

Test material

Constituent 1
Chemical structure
Reference substance name:
Oxycodone
EC Number:
200-960-2
EC Name:
Oxycodone
Cas Number:
76-42-6
Molecular formula:
C18H21NO4
IUPAC Name:
(1S,5R,13R,17S)-17-hydroxy-10-methoxy-4-methyl-12-oxa-4-azapentacyclo[9.6.1.0^{1,13}.0^{5,17}.0^{7,18}]octadeca-7(18),8,10-trien-14-one
impurity 1
Reference substance name:
Unknown impurity
IUPAC Name:
Unknown impurity
Test material form:
solid

Test animals / tissue source

Species:
rabbit
Strain:
New Zealand White

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Reversibility:
fully reversible
Irritation parameter:
conjunctivae score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Reversibility:
fully reversible
Irritation parameter:
iris score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Reversibility:
fully reversible

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Oxycodone base is non irritant to the eye.