Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Classification & Labelling & PBT assessment

GHS

General Information

Name:
Rohöl F12
Not classified
Implementation:
EU
Remarks:
Classification of physical hazards (see below) was made as recommended by the ECHA helpdesk (INC000000037591): In case a classification must be waived because it is not appropriate following reason for no classification was given: "conclusive but not sufficient for classification". According to the helpdesk this refers, for example, to cases where a substance has a particular state, e.g. it is a gas, and therefore cannot be classified as an oxidizing solid.
As a consequence, shale oil (Rohöl F12) as a liquid cannot be classified as an "oxidizing solid" or as a "gas under pressure" and as reason for no classification "conclusive but not sufficient for classification" was indicated. However, the actual reason for "no classification" is that the specific classification (as an oxidizing solid or as a gas under pressure) is "not applicable". This "reason", however, is not provided in IUCLID.

Related composition

Related composition:
Rohöl F12

Classificationopen allclose all

Explosives
Reason for no classification:
data conclusive but not sufficient for classification
Flammable gases and chemically unstable gases
Reason for no classification:
data conclusive but not sufficient for classification
Aerosols
Reason for no classification:
data conclusive but not sufficient for classification
Reason for no classification:
hazard class not assessed
Oxidising gases
Reason for no classification:
data conclusive but not sufficient for classification
Gases under pressure
Reason for no classification:
data conclusive but not sufficient for classification
Flammable liquids
Hazard category:
Flam. Liquid 3
Hazard statement:
H226: Flammable liquid and vapour.
Flammable solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-reactive substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric liquids
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-heating substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Substances and mixtures which in contact with water emit flammable gases
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising liquids
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising solids
Reason for no classification:
data conclusive but not sufficient for classification
Organic peroxides
Reason for no classification:
data conclusive but not sufficient for classification
Corrosive to metals
Reason for no classification:
data conclusive but not sufficient for classification
Desensitized explosives
Reason for no classification:
data lacking
Acute toxicity - oral
Reason for no classification:
data lacking
Acute toxicity - dermal
Reason for no classification:
data lacking
Acute toxicity - inhalation
Reason for no classification:
data lacking
Skin corrosion / irritation
Reason for no classification:
data lacking
Serious eye damage / eye irritation
Reason for no classification:
data lacking
Respiratory sensitisation
Reason for no classification:
data lacking
Skin sensitisation
Reason for no classification:
data lacking
Aspiration hazard
Reason for no classification:
data lacking
Reproductive toxicity
Reason for no classification:
data lacking
Effects on or via lactation
Reason for no classification:
data lacking
Germ cell mutagenicity
Reason for no classification:
data lacking
Carcinogenicity
Hazard category:
Carc. 1B
Hazard statement:
H350: May cause cancer <state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard>.
1. Specific target organ toxicity - single (STOT-SE)
Reason for no classification:
data lacking
1. Specific target organ toxicity - repeated (STOT-RE)
Reason for no classification:
data lacking
Hazardous to the aquatic environment (acute / short-term)
Reason for no classification:
data lacking
Hazardous to the aquatic environment (long-term)
Hazard category:
Aquatic Chronic 3
Hazard statement:
H412: Harmful to aquatic life with long lasting effects.
M-Factor chronic:
0
Hazardous to the ozone layer
Reason for no classification:
data lacking

Labelling

Signal word:
Danger

Hazard pictogram

GHS02: flame
GHS07: exclamation mark
GHS08: health hazard

Hazard statements

H226: Flammable liquid and vapour.
H315: Causes skin irritation.
H319: Causes serious eye irritation.
H350: May cause cancer <state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard>.
H412: Harmful to aquatic life with long lasting effects.

Precautionary statements

P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P273: Avoid release to the environment.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
Special protective clothing and face protection not necessary and can be deleting from the listing in P280
P302+P352: IF ON SKIN: Wash with plenty of water/…
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P370+P378: In case of fire: Use... to extinguish.
Use foam, powder or carbon dioxide fire extinguisher

Notes