Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study initiation date - 24 September 2003; Experiment start date - 26 September 2003; Experiment end date - 09 October 2003.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Identity: FAT 40812/A
Batch: WP 8/03
Purity: approx. 75 %
Appearance: Solid, dark red-brownish powder
Expiration date: 23 April 2010
Storage: At room temperature at about 20 °C
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Number of fragments:
0
Remarks on result:
not thermal sensitive if heated under defined confinement
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance is not an explosive.
Executive summary:

In a GLP compliant study, performed according to EU method A.14, the explosiveness of the test substance was determined. Experiments were performed six times and results indicate that the substance is not thermally sensitive, shock sensitive, or sensitive to friction. Therefore, it could be concluded that the test substance is not explosive.

Description of key information

In a GLP-compliant study, performed according to EU method A.14, the explosiveness of the test substance was determined. Experiments were performed six times and results indicate that the substance is not thermally sensitive, shock sensitive, or sensitive to friction. Therefore, it could be concluded that the test substance is not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification