Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
ethyl (2Z)-4,4,4-trifluoro-3-(methylamino)but-2-enoate
EC Number:
801-277-8
Cas Number:
507448-65-9
Molecular formula:
C7H10F3NO2
IUPAC Name:
ethyl (2Z)-4,4,4-trifluoro-3-(methylamino)but-2-enoate

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

 

1.      Test on Thermal Sensitivity (Effect of a Flame)

Steel sleeve test

 

Test No.

Nozzle-plate with 6 mm hole

Nozzle-plate with 2 mm hole

 

Explosion

Number of fragments

Explosion

Number of fragments

1

no

-

no

-

2

no

-

no

-

3

no

-

no

-

 

The substance is not thermally sensitive

 

2.      Test on Mechanical Sensitivity (shock)

Falling hammer

 

Test No.

Reaction

1

negative

2

Negative

3

Negative

4

Negative

5

Negative

6

negative

 

The substance is not shock sensitive

 

3.      Test on Mechanical Sensitivity (Friction)

This test was not done. 

The method is not suitable for liquids. 

 

 

Applicant's summary and conclusion

Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:

The substance is not considered an explosive, as conducted from the test results on:

1. Thermal sensitivity (effect of a flame)
2. Mechanical sensitivity (shock)

Mechanical sensitivity (friction): not tested.
The testing method is not suitable for liquids.

Executive summary:

 

The substance is not considered an explosive, as conducted from the test results on:

 

1.      Thermal sensitivity          (effect of a flame)

2.      Mechanical sensitivity     (shock)

 

Mechanical sensitivity (friction): not tested. 

The testing method is not suitable for liquids.