Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 8-11, 2010
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Naphthenic acids, reaction products with diethylenetriamine
EC Number:
268-610-1
EC Name:
Naphthenic acids, reaction products with diethylenetriamine
Cas Number:
68131-13-5
Molecular formula:
C16H21N3O2 (minimal)
IUPAC Name:
Naphthenic acids, reaction products with diethylenetriamine
Details on test material:
Chemical name:Naphthenic acids, reaction products with diethylenetriamine
Product name: MK195KSF
CAS RN: 68131-13-5
The sample was stored in the dark, at ambient temperature, in the container in which it was received until required for testing, when an appropriate subsample was provided for the test operator.

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
< 1.4
pH:
7
Remarks on result:
other: Temperature range: 20.79 to 21.11°C
Details on results:
Peak no. log10 POW
1 < 0
2 0.54
3 1.1
4 1.4
The test is described as valid for the quantitative estimation of log10 POW values in the range of 0 to 6. In those instances where the statistical treatment of the experimental data produces a calculated log10 POW value outside of this range then the final result is quoted as either < 0 or > 6 as appropriate.

Any other information on results incl. tables

The retention times from the individual injections and the derived k' values are given in Table 1. 

 

From the experimentally derived k’ measurements and the literature POWvalues of the reference substances (Ref 1), the equation of the fitted regression line was determined as:

 

log10POW= a.log10k’ + b

 

where,   a =slope

              b =intercept

 

These data are displayed graphically in Figure 1. The coefficient of determination (r2) of these data was calculated as 0.979 at pH 7,indicating an approximately linear relationship between log10POWand log10k’.

 

The test described has been validated for the quantitative estimation of log10POWvalues in the range 0 to 6 (Ref 1). In those instances where the statistical treatment of the experimental data produces a calculated log10POWvalue outside of this range then the final result is quoted as either < 0 or > 6 as appropriate.

 

At pH 7, the k’ for MK195KSFwas calculated for the 100 mg L-1test concentration only. The k’ values for a 100 mg L-1standard were 0.03, 0.26, 0.39 and 0.53 for Peaks 1, 2, 3 and 4, respectively. Therefore, the estimated log10POWfor MK195KSF at pH 7 is < 0, 0.54, 1.1 and 1.4 for Peaks 1, 2, 3 and 4, respectively.   

 

At pH 7,the k’ values for MK195KSFwere not calculated for the 10 and 50 mg L-1test concentrations. Peaks were observed at similar retention times to those obtained from the 100 mg L-1test concentrationand added confidence that peaks obtained were due to the test substance.

 

The pH of the mobile phase was nominally 7 (pH 7 buffer measured at 7.02). The temperature of the room in which the HPLC work was performed ranged between 20.79 to 21.11 °C.

Table 1          Reference Standards Retention times and derived k’ values – pH 7

Substancea

 

Retention time injection 1 (min)

Retention time injection 2 (min)

Mean retention time, tr(min)

Derived

k' valueb

log10POW

Sodium nitrate

1.005

1.002

1.004c

-

-

Acetanilide

1.306

1.308

1.307

0.30

1.0d

Toluene

2.998

3.013

3.006

2.00

2.7d

Naphthalene

3.715

3.721

3.718

2.71

3.6d

Biphenyl

5.314

5.303

5.309

4.29

4.0d

Phenanthrene

6.836

6.840

6.838

5.81

4.5d

ppDDT

23.738

23.722

23.730

22.65

6.5d

100 mg L-1standard Peak 1

1.033

1.037

1.035

0.03

< 0e

100 mg L-1standard Peak 2

1.262

1.267

1.265

0.26

0.54

100 mg L-1standard Peak 3

1.397

1.401

1.399

0.39

1.1

100 mg L-1standard Peak 4

1.532

1.535

1.534

0.53

1.4

a   sodium nitrate, acetanilide, biphenyl and phenanthrene were extracted at 240 nm whereas toulene and naphthalene were extracted at 215 nm. For the 100 mg L-1standards, Peaks 1, 2, 3 and 4 were extracted at 198, 220, 210 and 210, respectively.

b    k’= (tr-t0)/t0

 

c   this is the t0value used in the calculation of k¢

 

d   log10POWliterature value

 

e   quoted as < 0 as this method is only validated between log10POWvalues from 0 to 6

Applicant's summary and conclusion

Conclusions:
Peak no. log10 POW
1 < 0
2 0.54
3 1.1
4 1.4
The test is described as valid for the quantitative estimation of log10 POW values in the range of 0 to 6. In those instances where the statistical treatment of the experimental data produces a calculated log10 POW value outside of this range then the final result is quoted as either < 0 or > 6 as appropriate.