EC number: 273-729-7 | CAS number: 69012-29-9 By-product from the production of ferronickel from a complex ore. Consists primarily of oxides of aluminum, iron, magnesium and silicon.
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Short-term toxicity to aquatic invertebrates
Administrative data
Link to relevant study record(s)
Description of key information
According to the results of a short term aquatic toxicity test of slags, ferronickel-manufg. on aquatic invertebrates (Daphnia magma) the EC50 (48 h) of the test item is estimated to be > 100 mg /L (nominal). The corresponding EC0 (48 h) was 100 mg/L (nominal). This information is sufficient to support the lack of classification for acute aquatic toxicity, but for a PNEC derivation it is preferred to use information from long-term studies.
Key value for chemical safety assessment
Additional information
The toxicity of Slags, ferronickel-manufg./Electric Furnace Slag/Converter Slag on Daphnia magna was tested in a 48 hour acute immobilisation test. The test was performed according to OECD Guideline 202.
Slags, ferronickel-manufg./Electric Furnace Slag/Converter Slag, Batch No:09/2010/FI/CS; Test species:Daphnia magna Straus, Clone V, age between 6 and 24 hours. Twenty organisms per test concentration (4 replicates of 5 animals each) were used. The duration of the test was 48 hours. A static test with concentrations of 0, 1, 10 and 100 mg/L (nominal) was performed. Test solutions were prepared by stirring 100 mg test item per liter test medium for 48 hours to achieve a saturated solution. The insoluble particles of the test item were separated from the liquid phase by filtration through a filter with 0.45 µm mean pore size (according to OECD Series on Testing and Assessment No. 23). The lower test item concentrations of 10 and 1 mg/L were prepared by dilution of the filtrate. Defined volumes were applied to the test vessels. Endpoints reported are the EC50, EC100and EC0after 24 and 48 hours.Temperature, pH-value and oxygen concentration [% saturation] of the test solutions measured after 0, 24 and 48 hours are reported. Hardness of the test water was measured on the day of application.
The test was performed within the solubility limit of the test item. The maximum water solubility of the test item determined under test conditions for the nominal used concentration of 100 mg/L was not detectable for each of the analysed elements Al, Fe, Ni and Cr. Since the EC0and the EC50was found to be equal or above the maximum water solubility limit, the toxicological endpoints were evaluated using nominal concentrations of the test item.
The total hardness (as CaCO3) of the untreated control was determined to be 9°dH; the mean pH-value of the untreated control was determined to be8.270.15 (Std. Dev.), the mean temperature was measured to be 20.80.4 °C (Std. Dev.) and the mean oxygen saturation was determined to be 1000.8 % (Std. Dev.).
According to the results of the test theEC50(48 h)of the test item is estimated to be> 100 mg /L (nominal).The correspondingEC0(48 h)was100 mg/L (nominal). Therefore, no acute aquatic hazards were identified for aquatic invertebrates.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.