Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
FROM 30 AUG 2022 TO 05 OCT 2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2022
Report date:
2022

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
2019
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-amino-N-[6-cyano-5-(trifluoromethyl)-3- pyridyl]cyclobutanecarboxamide
Cas Number:
1950587-17-3
Molecular formula:
C12H11F3N4O
IUPAC Name:
1-amino-N-[6-cyano-5-(trifluoromethyl)-3- pyridyl]cyclobutanecarboxamide
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material: JNJ-63632283-AAA (T003665)
- Physical state: solid (powder)
- Appearance: white powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- lot/batch number of test material: 22BN0551
- Expiry date: 28 April 2023 (retest date)
- Physical Description: Off-white powder
- Purity test date: 23 May 2022 (certificate of analysis release date)
- Purity: 98.3%
- Purity correction factor: no correction factor required
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning time over 250 mm for metal powders or metal alloys
Burning time:
< 2 min

Any other information on results incl. tables

In contact with the flame of the gas burner the test material melted and turned into a brown residue. Grey smoke was observed. After removal of the ignition source, no propagation of combustion of the test material was observed.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The preliminary screening test was performed for the determination of the flammability of JNJ-63632283-AAA (T003665).
No propagation of combustion of the test material along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test material is considered ‘not flammable’.