Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-06-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Commission Regulation (EC) No 440/2008 of 30 May 2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), Method A.9, Official Journal of the European Union L 142 of 31 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH FLP
Specific details on test material used for the study:
Name: Reaction mass of dipentene and (Z)-3,7-dimethylocta-1,3,6,-triene
Public name: Ocimene PQ
EC number: 933-779-9 (pre-registration 222-081-3)
CAS number: n/a (pre-registration 3338-55-4)
Batch/Lot number: A170524D
Appearance: Colourless liquid
Purity: Considered as 100 %
Expiry date: 06 June 2019
Storage conditions: Room temperature (15-25 °C, ≤ 70 % relative humidity (RH)), under inert gas, protected from humidity (tightly closed container)
Key result
Flash point:
53.2 °C
Atm. press.:
100.2 kPa
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The measured flash point of Ocimene PQ was 53.2°C.
Executive summary:

The flash point of Ocimene PQ was determined in a continuous closed-cup according to EU guideline A.9. The measured flash point of Ocimene PQ was 53.2°C.

Description of key information

The flash point of Ocimene PQ was determined in a continuous closed-cup and according to EU guideline A.9. The measured flash point of Ocimene PQ was 53.2°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
53.2 °C

Additional information

Based on the results of the study, Ocimene PQ is classified as Category 3 (flammable liquids) according to GHS criteria.