Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 Jan 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction products of 2,2'-(1,3-phenylenebis(oxy))diethanol with 2-(phenoxymethyl)oxirane and 2-isocyanatoethyl methacrylate
Cas Number:
1431303-59-1
Molecular formula:
Not assigned for UVCB substance.
IUPAC Name:
Reaction products of 2,2'-(1,3-phenylenebis(oxy))diethanol with 2-(phenoxymethyl)oxirane and 2-isocyanatoethyl methacrylate
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Lot/batch number of test material: 6252020
- Purity: 100%
- Expiration date:September 2021

Results and discussion

Flash point
Key result
Flash point:
> 200 °C
Atm. press.:
771 mm Hg

Any other information on results incl. tables

The substance was brought to room temperature. The flame was introduced at 5 °C increments up to 200 °C. The preliminary test resulted in no observed flash at 200 °C. The substance did not change in appearance during the test. No vapors were observed to be liberated during the test.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point for ERGP-IEM was determined to be >200 °C (ASTM D3278).
Executive summary:

The flash point of ERGP-IEM was measured using a closed cup flash point apparatus. The study was tested up to 200 °C. No flash was observed up to 200 °C. The substance did not change in appearance during the test and no vapors were observed to be liberated during the test. The study was conducted in accordance with guideline ASTM D3278 and was GLP compliant. Therefore, this study is considered reliable without restrictions.