Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005
Report date:
2005

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
OECD Guideline No. 109 for the testing of chemicals,
adopted 27 July 1995.
GLP compliance:
yes
Type of method:
pycnometer method
Remarks:
Gas comparison pycnometer

Test material

Constituent 1
Test material form:
solid: particulate/powder
Details on test material:
Batch number: 022401
Specific details on test material used for the study:
purity: 79.8 %

Results and discussion

Density
Key result
Type:
relative density
Density:
1.26 other: (corresponds to D4(20))
Temp.:
22 °C

Applicant's summary and conclusion

Conclusions:
The mean relative density of STI571 F8 was determined to be 1.264 at 22 °C (two
samples).