Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Experimental start date: 30th January Experimental completion date: 16th May 2007 Study completion date: 12th June 2007
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: - Study generated according to generally valid and/or internationally accepted testing guidelines - Performed according to GLP - Test parameters based on specific testing guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- 92/69/EEC, A6 (Column Elution Method)
- Deviations:
- yes
- Remarks:
- First Amendment to Study Plan: Concerning: Schedule Alteration: New experimental completion date Reason for the alteration: Delay in study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Deviations:
- yes
- Remarks:
- First Amendment to Study Plan: Concerning: Schedule Alteration: New experimental completion date Reason for the alteration: Delay in study
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Water solubility:
- < 0.096 mg/L
- Temp.:
- 20 °C
- pH:
- ca. 6.9
- Details on results:
- WATER SOLUBILITY:
During the preliminary test the water solubility of FP-100 at room temperature was estimated by a simplified flask method to be lower than the smallest calibration point of 0.379 µg/mI. Therefore, the column elution method was used for the performance of the main test.
During the main test six samples have been analysed in the first run (0.52 mI/min) and six samples during the second run (0.26 mI/min), each with a sampling interval of one hour. Total elution time was 93 hours. The sample measurement was performed by HPLC.
The measured results differ by less than 30 %. Therefore, the study is considered to be valid.
The r2 fit was 0.9994 (optimum 1.0000). This reflects the linearity of the HPLC-system within the calibration range of 0.09615 to 32.05 mg/I of the test item.
In conclusion, the water solubility of FP-100 at 20°C was determined to be below the smallest point of calibration, which is
<0.096 mg/l using the column elution method.
The water solubility was not corrected for the purity of the test item. - Conclusions:
- Interpretation of results (migrated information): insoluble (< 0.1 mg/L)
The water solubility of FP-100 at 20°C was determined to be below the smallest point of calibration, which is <0.096 mg/I using the column elution method. - Executive summary:
Not provided
Reference
Description of key information
During this study the water solubility and the partition coefficient of FP-100 were determined. The water solubility of FP-100 at 20°C was determined to be below the smallest point of calibration, which is <0.096 mg/I using the column elution method.
Key value for chemical safety assessment
- Water solubility:
- 0.096 mg/L
- at the temperature of:
- 20 °C
Additional information
During the preliminary test the water solubility of FP-100 at room temperature was estimated by a simplified flask method to be lower than the smallest calibration point of 0.379 µg/mI. Therefore, the column elution method was used for the performance of the main test.
During the main test six samples have been analysed in the first run (0.52 mI/min) and six samples during the second run (0.26 mI/min), each with a sampling interval of one hour. Total elution time was 93 hours. The sample measurement was performed by HPLC.
The measured results differ by less than 30 %. Therefore, the study is considered to be valid.
The r2fit was 0.9994 (optimum 1.0000). This reflects the linearity of the HPLC-system within the calibration range of 0.09615 to 32.05 mg/I of the test item.
In conclusion, the water solubility of FP-100 at 20°C was determined to be below the smallest point of calibration, which is
<0.096 mg/l using the column elution method.
The water solubility was not corrected for the purity of the test item.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.