Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ASTM D7094
GLP compliance:
no
Type of method:
other: modified continuously closed cup
Flash point apparatus:
other: automatic apparatus (Miniflash FLP Touch by Grabner Instruments)
Key result
Remarks on result:
other: no flash point up to 200°C
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the substance, measured with an automatic apparatus according to ASTM D7094 standard, was not found below 200°C.

Description of key information

No flash point up to 200°C

Key value for chemical safety assessment

Additional information