Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
The substance is formed during the industrial process (it is a soap) and therefore there is no exposure via inhalation nor dermal.

Column 2 of Annex VIII 8.5 states: "In addition to the oral route (Annex VII, 8.5.1.), for substances other than gases, the information mentioned under 8.5.2 to 8.5.3 shall be provided for at least one other route. The choice for the second route will depend on the nature of the substance and the likely route of human exposure. If there is only one route of exposure, information for only that route needs to be provided." Furthermore Column 2 of Annex VIII 8.5.2 states: "Testing by the inhalation route is appropriate if exposure of humans via inhalation is likely taking into account the vapour pressure of the substance and/or the possibility of exposure to aerosols, particles or droplets of an inhalable size."

The vapour pressure of the substance if very low (1 x 10-4 Pa at 25 °C) and a boiling point result was not possible to obtain as the substance decomposes before boiling, as such the substance is considered to be of low volatility. Furthermore the possibility of exposure to aerosols, particles or droplets of an inhalable size is not expected as the substance (soap) is formed within the production tank of the grease (mixture). This tank is closed, this process requires heating and the workers will not be in contact with the product whilst it is still hot.

Towards the end of the process, some workers could be in contact with the product during grinding, deaeration, and packaging. Contacts would essentially be by hands. – Workers wear PPE, including chemical gloves and safety glasses. Particle size distribution was not conducted as the substance is marketed or used in a non-solid or granular form and therefore exposure via the inhalation route is not expected.

In conclusion there is no expected exposure via the inhalation route and therefore an acute toxicity inhalation study is not considered to be necessary.
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 May 2018 to 25 May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
Not reported
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
Not reported
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: isothermal thermogravimetry
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 Pa
Test no.:
#3
Temp.:
25 °C
Vapour pressure:
0 Pa
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Mean vapour pressure

For run 1, there was initial high weight losses at lower temperatures. This was indicative of degassing of the sample. Only the data from runs 2 and 3 have therefore been used for calculations.

Table 1: A summary of the run 2 and 3 results

 Parameter  Run 2  Run 3
 Correlation (R2)  0.9941  0.9965
 Slope  -4134  -4490
 Intercept  10.19  10.90
 log10PT at 25 °C  -3.7  -4.2
 PT (Pa) at 25 °C  0.00021  0.000069

Table 2: Vapour Pressure Measurements (Run 2)

 Temperature (°C)  Evaporation rate, VT (g/minute) log10VT   log10PT
 118.63  0.0000002613  -4.098  -0.3745
 123.61  0.0000003556  -3.964  -0.2313
 128.59  0.0000004873  -3.827  -0.0849
 133.58  0.0000006356  -3.712  0.0386
 138.56  0.0000007712  -3.628  0.1285

Table 3: Vapour Pressure Measurements (Run 3)

 Temperature (°C)  Evaporation rate, VT(g/minute) log10VT   log10PT
 123.64  0.0000002342  -4.145  -0.4253
 128.61  0.0000003325  -3.993  -0.2625
 133.58  0.0000004368  -3.874  -0.1357
 138.55  0.0000005693  -3.759  -0.01259
Conclusions:
The vapour pressure of the test item was determined to be 1 x 10-4 Pa at 25 °C.
Executive summary:

The vapour pressure of the test item was determined in a study following OECD 104 and EC Method A.4 guidelines, using the effusion method. The vapour pressure of the test item was determined to be 1 x 10-4 Pa at 25 °C.

 

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
boiling point
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a solid which decomposes before boiling
Justification for type of information:
In accordance with column 2 of REACH Annex VII, the boiling point study does not need to be conducted as the substances decompose before boiling.
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
particle size distribution (granulometry)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is marketed or used in a non solid or granular form
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
In accordance with column 2 of REACH Annex VII, the granulometry study does not need to be conducted as the substance is marketed or used in a non-solid or granular form.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion