Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-02-14 to 2017-06-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CIPAC Handbook Volume K: Analysis of Technical and Formulated Pesticides, CIPAC MT 187
Version / remarks:
2003
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
other: particle volume or particle mass

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2'-[[3-chloro-4-[[4-[[2-(sulphooxy)ethyl]sulphonyl]phenyl]azo]phenyl]imino]bisethyl bis(hydrogen sulphate), potassium sodium salt
EC Number:
287-719-5
EC Name:
2,2'-[[3-chloro-4-[[4-[[2-(sulphooxy)ethyl]sulphonyl]phenyl]azo]phenyl]imino]bisethyl bis(hydrogen sulphate), potassium sodium salt
Cas Number:
85567-07-3
Molecular formula:
C36H42Cl2KN6NaO28S8
IUPAC Name:
2,2'-[[3-chloro-4-[[4-[[2-(sulphooxy)ethyl]sulphonyl]phenyl]azo]phenyl]imino]bisethyl bis(hydrogen sulphate), potassium sodium salt
Test material form:
solid
Details on test material:
Batch: 1283067001

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D50
Mean:
35.39 µm
St. dev.:
1.43
Remarks on result:
other:
Remarks:
Mean of two measurements
Percentile:
D10
Mean:
9.49 µm
St. dev.:
0.73
Remarks on result:
other:
Remarks:
Mean of two measurements
Percentile:
D90
Mean:
105.44 µm
St. dev.:
3.05
Remarks on result:
other:
Remarks:
Mean of two measurements

Any other information on results incl. tables

Particle Size Distribution:

 

Measurement 1

[µm]

Measurement 2

[µm]

Average

[µm]

L10D(v, 0.1)

8.969

10.008

9.49

L50D(v, 0.5)

34.379

36.402

35.39

L90D(v, 0.9)

103.284

107.600

105.44

Applicant's summary and conclusion

Conclusions:
The L10 D (v, 0.1) was determined to be 9.49 µm, the L50 D (v, 0.5) was determined to be 35.39 µm and the L90 D (v, 0.9) was determined to be 105.44 µm.
Executive summary:

The particle size distribution was determined using the laser diffraction method with dry dispersion. The particle size distribution of test item was determined following CIPAC MT 187. The dispersing energy was adjusted to 3.0 bar.

Two measurements have been performed. The following results were obtained. The L10D (v, 0.1) was determined to be 9.49 µm, the L50D (v, 0.5) was determined to be 35.39 µm and the L90D (v, 0.9) was determined to be 105.44 µm.