Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Qualifier:
no guideline followed
Principles of method if other than guideline:
The vapour pressure is estimated by calculation. The software (EPISuite MPBPVP (v1.43)) uses three different methods (Antoine method, modified grain method, Mackay method) to estimate the vapour pressure based on melting point and boiling point of the substance.
GLP compliance:
no
Type of method:
other: Calculation
Specific details on test material used for the study:
SMILES: CCCCCCCCCCCCCCCC(=O)(OCC(COC(=O)(CCCCCCCC=CCC=CCCCCC))OC(=O)(CCCCCCCCCCCCCCCCCCC)); MOL FOR: C57 H106 O6; MOL WT : 887.48;
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Antoine method
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Modified Grain Method
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Mackay Method

Vapor Pressure Estimations (25 deg C):

(Using BP: 825.66 deg C (estimated))

(Using MP: 349.84 deg C (estimated))

VP: 6.59E-035 mm Hg (Antoine Method)

: 8.78E-033 Pa (Antoine Method)

VP: 1.26E-020 mm Hg (Modified Grain Method)

: 1.68E-018 Pa (Modified Grain Method)

VP: 7.5E-020 mm Hg (Mackay Method)

: 9.99E-018 Pa (Mackay Method)

Conclusions:
The estimates for the vapour pressure of menhaden oil are below 1E-17 Pa for all three methods used.
Executive summary:

The given vapour pressure of menhaden oil is calculated from estimated melting and boiling point by MPBPVP, using EPI Suite. All three used models predict very low values for the vapour pressure at 25°C (< 1E-17 Pa). The EPA recommend that EPI Suite is a screening-level tool and should not be used if acceptable measured values are available.

Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Qualifier:
no guideline followed
Principles of method if other than guideline:
The vapour pressure is estimated by calculation. The software (EPI Suite MPBPVP (v1.43)) uses three different methods (Antoine method, modified grain method, Mackay method) to estimate the vapour pressure based on melting point and boiling point of the substance.
GLP compliance:
no
Type of method:
other: Calculation
Specific details on test material used for the study:
SMILES : O=C(CCCCCCCCCCCCCCCCC)OCC(OC(=O)(CCCCCCCCCCCCCCCC))COC(=O)(CCCCCCCCCCCCCCC); CHEM: Glycerides, C16-18; MOL FOR: C54 H104 O6; MOL WT: 849.43;
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Antoine Method
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Modified Grain Method
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Mackay Method

Vapor Pressure Estimations (25 deg C):

(Using BP: 783.70 deg C (estimated))

(Using MP: 58.00 deg C (user entered))

VP: 1.7E-027 mm Hg (Antoine Method)

: 2.27E-025 Pa (Antoine Method)

VP: 4.5E-016 mm Hg (Modified Grain Method)

: 6E-014 Pa (Modified Grain Method)

VP: 8.46E-016 mm Hg (Mackay Method)

: 1.13E-013 Pa (Mackay Method)

Conclusions:
The estimates for the vapor pressure of Glycerides, C16-18 are below 2.0E-13 Pa for all three methods used.
Executive summary:

The given vapor pressure of Glycerides, C16 -18 is calculated from melting and boiling point by MPBPVP, using EPI Suite. All three used models predict very low values for the vapor pressure at 25°C (< 2e-13 Pa). The EPA recommend that EPI Suite is a screening-level tool and should not be used if acceptable measured values are available.

Description of key information

Calculations predict very low values (< 2x10-13Pa) for the vapour pressure of menhaden oil and other triglycerides of long chain fatty acids. Therefore, the vapour pressure of menhaden oil is negligible. 

Key value for chemical safety assessment

Additional information