Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 226-827-9 | CAS number: 5495-84-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 26 June 2017 to 04 August 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- 1995
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Key result
- Water solubility:
- 0.34 mg/L
- Conc. based on:
- test mat.
- Temp.:
- 20 °C
- pH:
- > 5.87 - < 6.45
- Remarks on result:
- other: RSD = 0.2 %
- Details on results:
- PRELIMINARY TEST
- The preliminary test at room temperature showed, that the water solubility of the test material was below 9.54 mg/L. The solubility of the test material in water at room temperature was estimated to be < 9.54 mg/L. Therefore, the column elution method was performed.
MAIN TEST
- The mean value and its standard deviation from five consecutive samples taken from the saturation plateau, each measured twice, were calculated for each run. The mean concentrations calculated on two tests using different flows were compared and the repeatability was calculated, which should be better than 30 %.
- The first column yielded in a mean value of the water solubility of 0.335 mg/L with a RSD of 0.01 % which meets the criterion of < 30 %.
- The second column yielded in a mean value of the water solubility of 0.335 mg/L with a RSD of 0.02 % which meets the criterion of < 30 %.
- The third column (blank) showed no test material in the water or any signals in the HPLC chromatograms.
- The two columns with different flow rates yielded in a mean value of the water solubility of 0.335 mg/L with a RSD of 0.2 % which meets the criterion of < 30 %.
- To verify the accuracy of the analytical method freshly prepared standard solutions (prepared with the test material) were measured in between the samples of the column elution method.. The recovery rates should lie between 90 and 110 %.
- The recovery rate of the measured standard solutions was in the range from 96.6 to 107.4 %, which shows a good accuracy of the analytical method.
- Following the measurements, the amount of the test material in the columns was checked. For this purpose, columns 1 and 2 were each purged with 100 mL acetone. 0.01 mL of the acetone solutions were diluted to 1 mL with the eluent and measured by HPLC.
- These measurements show, that 9.66 mg of the test material could be found in column 1 after the main test, which corresponds to 75.3 % of the starting amount. 9.64 mg of the test material could be found in column 2 after the main test, which corresponds to 75.1 % of the starting amount. In both columns enough test material could be found after the main tests to ensure correct performance of the test. - Conclusions:
- Under the conditions of this study the water solubility of the test material was 0.34 mg/L.
- Executive summary:
The water solubility of the test material was investigated in accordance with the standardised guidelines OECD 105 and EU Method A.6, under GLP conditions.
A preliminary test was performed to give an estimate of the water solubility in order to decide which method had to be used for the main test. In the preliminary test, the solubility of the test material in water at room temperature was estimated to be < 9.54 mg/L, therefore the column elution method was performed. The water solubility of the test material was tested in two columns, a third column was filled with sand which was not loaded with the test material as blank. The concentrations in the fractions were determined by means of HPLC.
The two columns with different flow rates yielded in a mean value of the water solubility of 0.335 mg/L with a RSD of 0.2 % which meets the criterion of < 30 %. The recovery rate of the measured standard solutions was in the range from 96.6 to 107.4 %, which shows a good accuracy of the analytical method.
Following the measurements, the amount of the test material in the columns was checked. For this purpose, columns 1 and 2 were each purged with 100 mL acetone. 0.01 mL of the acetone solutions were diluted to 1 mL with the eluent and measured by HPLC. In both columns enough test material could be found after the main tests to ensure correct performance of the test.
Under the conditions of this study the water solubility of the test material was 0.34 mg/L at 20 °C.
Reference
Table 3:Summarised results of column 1 and 2
Column |
Mean concentration (mg/L) |
Mean measured concentration (mg/L) |
Relative standard deviation (RSD) (%) |
1 |
0.335 |
0.335 |
0.2 |
2 |
0.335 |
Description of key information
Under the conditions of this study the water solubility of the test material was 0.34 mg/L.
Key value for chemical safety assessment
- Water solubility:
- 0.34 mg/L
- at the temperature of:
- 20 °C
Additional information
The water solubility of the test material was investigated in accordance with the standardised guidelines OECD 105 and EU Method A.6, under GLP conditions.
A preliminary test was performed to give an estimate of the water solubility in order to decide which method had to be used for the main test. In the preliminary test, the solubility of the test material in water at room temperature was estimated to be < 9.54 mg/L, therefore the column elution method was performed. The water solubility of the test material was tested in two columns, a third column was filled with sand which was not loaded with the test material as blank. The concentrations in the fractions were determined by means of HPLC.
The two columns with different flow rates yielded in a mean value of the water solubility of 0.335 mg/L with a RSD of 0.2 % which meets the criterion of < 30 %. The recovery rate of the measured standard solutions was in the range from 96.6 to 107.4 %, which shows a good accuracy of the analytical method.
Following the measurements, the amount of the test material in the columns was checked. For this purpose, columns 1 and 2 were each purged with 100 mL acetone. 0.01 mL of the acetone solutions were diluted to 1 mL with the eluent and measured by HPLC. In both columns enough test material could be found after the main tests to ensure correct performance of the test.
Under the conditions of this study the water solubility of the test material was 0.34 mg/L at 20 °c.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.