Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15.09. - 05.10.05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
92/69/EWG
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Key result
Type:
relative density
Density:
1.271 other: dimensionless
Temp.:
15 °C

A crucible was balanced filled with the test 4.80 g of the test substance. The sample was inserted into the Micromeritics AccuPyc 1330 and the measurement was started. The measuring cycle consisted of five individual measurements.

 

Measurement 1

1.2704 g/cm3

Measurement 2

1.2705 g/cm3

Measurement 3

1.2704 g/cm3

Measurement 4

1.2704 g/cm3

Measurement 5

1.2706 g/cm3

Conclusions:
The test item has a relative density of 1.271.
Executive summary:

A study was performed according to 92/69/EWG using a Micromeritics AccuPyc 1330 pnyctometer. A crucible was balanced and filled with the test 4.80 g of the test substance. The sample was inserted into the Micromeritics AccuPyc 1330 and the measurement was started. The measuring cycle consisted of five individual measurements. The test item has a relative density of 1.271.

Description of key information

Key value for chemical safety assessment

Relative density at 20C:
1.271

Additional information

A study was performed according to 92/69/EWG using a Micromeritics AccuPyc 1330 pnyctometer. Acrucible was balanced and filled with the test 4.80 g of the test substance. The sample was inserted into the Micromeritics AccuPyc 1330 and the measurement was started. The measuring cycle consisted of five individual measurements.The test item has a relative density of 1.271.