Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 222-824-1 | CAS number: 3623-51-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 6 Feb 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 015
- Report date:
- 2015
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Version / remarks:
- 2013
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Hess. Ministerium für Umwelt, Energie, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Test material
- Reference substance name:
- L-menthol
- EC Number:
- 218-690-9
- EC Name:
- L-menthol
- Cas Number:
- 2216-51-5
- Molecular formula:
- C10H20O
- IUPAC Name:
- (1R,2S,5R)-2-isopropyl-5-methyl-cyclohexanol
Constituent 1
Test animals / tissue source
- Species:
- cattle
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- TEST METHOD
The bovine corneal opacity and permeability (BCOP) test method is designed to measure the opacity of the cornea by quantifying the ability of light to pass through it.The permeability, as a result of the irritation potential of the test item, is determined using sodium fluorescein solution. The comparison of the opacity before and after the exposure to the test item and the determination of the permeability after the treatment provide an indication of the damaging effect of the test item. For this purpose the induction of opacity and increased permeability in an isolated bovine cornea after application of the test item was measured. The results of both criteria were combined. The resulting in vitro irritation factor (IVIS) was compared with the classification "no category (GHS)", "no prediction can be made", and "serious eye damaging" (CLP/EPA/GHS (Cat 1)).
IDENTIFICATION OF THE SOURCE OF THE EYES, STORAGE AND TRANSPORT CONDITIONS
- Source: Schlachthof Bensheim, Bensheim, Germany
- Donor animals: at least 9 month old
- Time interval prior to initiating testing: The corneae were isolated on the same day after delivery of the eyes. The cornea were directly used in the BCOP test on the same day.
- Transport medium and temperature conditions: Hank's Buffered Salt Solution (HBSS) supplemented with penicillin/streptomycin at ambient temperature.
PREPARATION OF THE EYES (BEFORE EXPOSURE)
- Eyes free of defects (scratches, neovascularisation, pigmentation, opacity): yes
- Dissection of the eyes and treatment: The cornea was carefully removed from the eye using scalpel and rounded scissors. A rim of about 2 mm of tissue (sclera) was left for stability and handling of the isolated cornea. Each cornea was mounted in a specially designed cornea holder.
- Description of the cornea holder: The cornea holder consists of anterior and posterior compartments, which interface with the epithelial and endothelial sides of the cornea, respectively.
- Test medium used in the cornea holder: The incubation medium consisted of MEM, supplemented with 1.1 g/500 mL sodium bicarbonate, 5 mL/500 mL L-glutamine, 100 U/mL penicillin and 100 µg/mL streptomycin. Immediately before starting the test, MEM was supplemented with 1% fetal calf serum.
- Equilibration time: 1 h at 32 ± 1°C
- Quality check of the equilibrated corneas: At the end of the equilibration period, the basal opacity was determined (t0). Each cornea with a value of the basal opacity >7 was discarded.
DETERMINATION OF THE INITIAL OPACITY
- Method: Corneal opacity was determined by the amount of light transmission passing through the cornea via an opacitometer.
- Specification of the device: OP_KiT opacitometer (Electro Design, France)
Test system
- Vehicle:
- physiological saline
- Controls:
- other: number of eyes for the negative control: 3; number of eyes for the positive control: 3
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 0.75 mL
- Concentration: 20% (with large particles) (w/v) in saline
After preparation of the 20% solution (with large particles) it was taken for 20 min in the ultrasonic bath. The test item could not be suspended homogeneously.
POSITIVE SUBSTANCE
- 10% (w/v) benzalkonium chloride in saline
- Amount applied in the test: 0.75 mL
NEGATIVE CONTROL/VEHICLE
- 0.9% NaCl (w/v) solution in deionised water (saline)
- Amount applied: 0.75 mL - Duration of treatment / exposure:
- 240 min at 32 ± 1°C
- Observation period (in vivo):
- Not applicable
- Number of animals or in vitro replicates:
- number of eyes for the test item: 3
- Details on study design:
- TEST CONDITIONS
- Short description of the method used: The endothelial side of the cornea was positioned against the sealing ring (O-ring) of the posterior part of the holder. The cornea was gently flattened over the O-ring but stretching was avoided. The anterior part of the holder was positioned on the top of the cornea and fixed in place with screws. Both compartments of the holder were filled with incubation medium. The posterior compartment was filled first to return the cornea to its natural convex position. The anterior compartment received the test item or the controls on the surface of the corneae. The corneae were incubated in a horizontal position at 32 ± 1 °C in the water-bath for 240 minutes.
POST-EXPOSURE TREATMENT
- Removal of the test substance: The test item was rinsed off from the application side with saline. However, the test item could not be rinsed off completely from the cornea. Some residue was visible after intensive rinsing.
DETERMINATION OF THE FINAL OPACITY
- Method: Corneal opacity was determined by the amount of light transmission through the cornea via an opacitometer.
- Time of determination: Directly after refilling fresh incubation medium in the anterior compartment the final opacity was measured (t240).
- Specification of the device: OP_KiT opacitometer (Electro Design, France)
DETERMINATION OF THE CORNEAL PERMEABILITY:
- Method: After the final opacity measurement was performed, the incubation medium was removed from the anterior compartment and replaced by sodium fluorescein solution. Corneae were incubated again in horizontal position for 90 ± 10 min in a water-bath at 32 ± 1 °C. The amount of sodium fluorescein that crosses into the posterior chamber was quantitatively measured with a spectrophotometer as optical density at 490 nm (OD490).
- Amount and concentration of the dye: 1 mL sodium fluorescein solution (0.5% (w/v); dissolved in HBSS)
- Incubation time: 90 ± 10 min at 32 ± 1 °C
- Treatment for measuring: Complete medium from the posterior compartment was removed, well mixed, transferred into a 96 well plate and OD490 was determined.
- Specification of the spectrophotometer: Versamax Molecular Devices
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- 240 min
- Value:
- 6.86
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
In vivo
- Irritant / corrosive response data:
- With the negative control (0.9% (w/v) NaCl solution in deionised water) neither an increase of opacity nor permeability of the corneae could be observed.
The positive control (10% (w/v) benzalkonium chloride in saline) showed clear opacity of the corneae corresponding to a classification as serious eye damaging.
Relative to the negative control, the test item caused any slight increase of the corneal opacity but not of the permeability. The calculated mean IVIS was 6.86. In the calculation, only two treated bovine eyes of three were included because the values of one eye were considered as outliers. Based on the experimental results the test substance is not classified as corrosive (Eye Cat. 1) but no prediction for the damage hazard can be made.
Any other information on results incl. tables
Table 1: Results after 240 min incubation time
Test group |
Opacity value = Difference (t240-t0) of Opacity |
Permeability at 490 nm (OD490) |
IVIS |
Mean IVIS |
||
|
Mean |
|
Mean |
|
|
|
Negative control |
0 |
0.00 |
0.063 |
0.063 |
0.95 |
0.95 |
0 |
0.065 |
0.98 |
||||
0 |
0.061 |
0.92 |
||||
Positive control |
96.00* |
0.045* |
96.68 |
101.85 |
||
90.00* |
0.041* |
90.62 |
||||
118.00* |
0.017* |
118.26 |
||||
Test substance |
7.00* |
0.873* |
20.10 |
|
||
7.00* |
0.046* |
7.69 |
6.86 |
|||
5.00* |
0.068* |
6.02 |
*corrected values
grey shaded groups were not included in calculation because the values are outliers
Applicant's summary and conclusion
- Interpretation of results:
- other: non-corrosive
- Remarks:
- according to Regulation (EC) No 1272/2008
- Conclusions:
- The corneal damage potential of the test substance was assessed in the BCOP assay using three fresh bovine corneae. The calculated mean IVIS was 6.86 (only two treated bovine eyes were included, the third was considered as outlier). According to OECD 437 the test item's hazard for eye damaging cannot be predicted but the test item is not classified as Eye Cat. 1.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.