Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 09 April 2006 and 21 April 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Sponsor's identification: BHES-100X
Description: white solid block
Batch number: 5K0718-CC
Date received: 21 January 2006
Storage conditions: room temperature, over silica gel, in the dark



Key result
Remarks on result:
no flash point - measurement carried out until boiling temperature

The results are presented in the table below

Temperature (°C)

Observations

25

No Flash

30

No Flash

35

No Flash

40

No Flash

45

No Flash

50

No Flash

55

No Flash

60

No Flash

65

No Flash

70

No Flash

75

No Flash

75 (fresh sample)

No Flash

80

No Flash

85

No Flash

90

No Flash

95

No Flash

100

No Flash

105

No Flash

110

No Flash

115 (fresh sample)

No Flash

120

No Flash

125

No Flash

130

No Flash

135

No Flash

140

No Flash

145

No Flash

150

No Flash

155

No Flash

160

No Flash

165

No Flash

165 (fresh sample)

No Flash

170

No Flash

175

No Flash

180

No Flash

185

No Flash

190

No Flash

195

No Flash

200

No Flash

205

A blue flash spread across the sample cup

200 (fresh sample)

No Flash

201

No Flash

202

No Flash

203

No Flash

204

No Flash

205 (fresh sample)

No Flash. The sample boiled

203 (fresh sample)

No Flash. The sample boiled

201 (fresh sample)

No Flash. The sample boiled

199 (fresh sample)

No Flash

201 (fresh sample)

No Flash. The sample boiled

201 (fresh sample)

No Flash. The sample boiled

199 (fresh sample)

No Flash

199 (fresh sample)

No Flash

Interpretation of results:
GHS criteria not met
Conclusions:
The test material has been determined not to have a flash point below its boiling temperature.
Executive summary:

The flash point was determined using a closed cup equilibrium method, Method A9 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive

67 /548/EEC). The test material has been determined not to have a flash point below its boiling temperature.

Description of key information

The flash point was determined using a closed cup equilibrium method, Method A9 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67 /548/EEC). The test material has been determined not to have a flash point below its boiling temperature.

Key value for chemical safety assessment

Additional information