Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1992
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: According to OECD 209, but limited documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report date:
1992

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3-hydroxy-2'-methoxy-2-naphthanilide
EC Number:
205-206-6
EC Name:
3-hydroxy-2'-methoxy-2-naphthanilide
Cas Number:
135-62-6
Molecular formula:
C18H15NO3
IUPAC Name:
3-hydroxy-N-(2-methoxyphenyl)naphthalene-2-carboxamide

Sampling and analysis

Analytical monitoring:
no

Test solutions

Details on test solutions:
Due to the low solubility no stock solution was used. The test item was weighed directly into the test vessels.

Test organisms

Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Origin: sewage treatment plant at Frankfurt am Main, Sindlingen (domestic activated sludge)
- Pretreatment: corresponding to the cited test guideline

Study design

Test type:
static
Water media type:
freshwater
Total exposure duration:
3 h

Test conditions

Test temperature:
20 ± 2°C
pH:
7.2 ± 0.2
Nominal and measured concentrations:
Nominal concentrations: 500 and 1 000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: Glasbottles with a diameter of 60 mm and a grounded neck (NS 29), height 170 mm, total volume appr. 480 ml. The bottles contained magnetic stirrer bars and were incubated in a water bath on magnetic stirrers.
- Test volume: 200 ml each batch
- No. of vessels per concentration (replicates): 2
- No. of vessels per control (replicates): 3
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol

Results and discussion

Effect concentrations
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The test item is not toxic at a concentration of 1000 mg/L to activated sludge of a municipal sewage treatment plant.
Executive summary:

A Respiration Inhibition Test according to OECD Guideline No. 209 was performed with the test item at Hoechst AG, Abteilung Umweltschutz, Frankfurt. The respiration rate of test item was measured after a contact time of three hours. The EC50 is > 1000 mg/L to activated sludge.