Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 441-520-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 19 March 2011 to 14 April 2011
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- 1995
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Version / remarks:
- 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Key result
- Water solubility:
- < 0.01 mg/L
- Conc. based on:
- test mat.
- Incubation duration:
- >= 64 - <= 114 h
- Temp.:
- 20 °C
- pH:
- >= 7.01 - <= 7.25
- Details on results:
- CALIBRATION
- Concentrations of the calibration samples were 0.1, 0.2, 0.5, 2, 5, 10 and 20 μg/mL. The calibration graph was calculated applying weighted linear regression using 1/concentration as weighting factor.
ANALYSIS OF THE TEST MATERIAL SAMPLES
- Measured concentrations of the test material on the two parallel columns using two different flow rates were recorded.
- Most of the measured values were below the quantitation limit; therefore calculation of the mean value is not feasible.
- Based on the measured data water solubility of the test material was considered to be less than 0.01 μg/mL (corresponds to the quantitation limit of the analytical method corrected with the tenfold concentration factor) at 20 ± 1°C. - Conclusions:
- Under the conditions of this study, the water solubility of the test material was considered to be less than 0.01 μg/mL (corresponds to the quantitation limit of the analytical method corrected with the tenfold concentration factor) at 20 ± 1°C.
- Executive summary:
The water solubility of the test material was investigated in accordance with the standardised guidelines OECD 105 and EU Method A.6, under GLP conditions.
The column elution method was applied and samples were analysed with high performance liquid chromatography (HPLC). Two parallel tests were performed.
Measured concentrations of the test material on the two parallel columns using two different flow rates were recorded. Most of the measured values were below the quantitation limit; therefore calculation of the mean value was not feasible.
Under the conditions of this study, the water solubility of the test material is considered to be less than 0.01 μg/mL (corresponds to the quantitation limit of the analytical method corrected with the tenfold concentration factor) at 20 ± 1°C.
Reference
Table 1: Results of the determination of the test material concentrations
Analytical occasion/ Time period (hours) |
Flow rate (mL/hour) |
Measured concentration of the test material (mg/L) |
|||
Concentration |
pH |
Concentration |
pH |
||
11 April 2011 / 64 |
~25 |
* |
7.07 |
* |
7.01 |
11 April 2011 / 72 |
* |
7.10 |
* |
7.10 |
|
12 April 2011 / 88 |
* |
7.12 |
* |
7.15 |
|
12 April 2011 / 96 |
* |
7.09 |
* |
7.11 |
|
13 April 2011 / 112 |
* |
7.13 |
* |
7.09 |
|
28 March 2011 / 66 |
~12.5 |
* |
7.18 |
* |
7.22 |
28 March 2011 / 74 |
* |
7.21 |
* |
7.23 |
|
29 March 2011 / 90 |
* |
7.18 |
* |
7.23 |
|
29 March 2011 / 98 |
* |
7.25 |
* |
7.21 |
|
30 March 2011 / 114 |
* |
7.22 |
* |
7.20 |
* below the quantitation limit
Description of key information
Under the conditions of the study, the water solubility of the test material was considered to be less than 0.01 μg/mL (corresponds to the quantitation limit of the analytical method corrected with the tenfold concentration factor) at 20 ± 1°C.
Key value for chemical safety assessment
Additional information
The water solubility of the test material was investigated in accordance with the standardised guidelines OECD 105 and EU Method A.6, under GLP conditions. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).
The column elution method was applied and samples were analysed with high performance liquid chromatography (HPLC). Two parallel tests were performed.
Measured concentrations of the test material on the two parallel columns using two different flow rates were recorded. Most of the measured values were below the quantitation limit; therefore calculation of the mean value was not feasible.
Under the conditions of the study, the water solubility of the test material was considered to be less than 0.01 μg/mL (corresponds to the quantitation limit of the analytical method corrected with the tenfold concentration factor) at 20 ± 1°C.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.