Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
GLP compliance:
yes (incl. QA statement)
Type of method:
differential thermal analysis

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
471-140-1
EC Name:
-
Cas Number:
121240-56-0
Molecular formula:
C16H37F2P
IUPAC Name:
hydrogen tetrabutylphosphanium difluoride

Results and discussion

Boiling point
Remarks on result:
other: Up to decomposition at 160°C, no boiling point was measurable. Starting at 140°C an exothermic reaction was detected. Most likely the crucible material (aluminum) reacted with the sample.