Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 2021 to December 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch number: CT20201015
Re-test date:10th September 2022
Storage conditions: store in a cool dry place
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0
Moisture (wt %):
0.03
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item 6FDA does not meet the GHS criteria for a flammable solid
Executive summary:

The flammability of the test item 6FDA was determined according to EU Method A.10.  The test item melted in contact with the ignition source.  A localised small to medium orange flame was produced, there was no further propagation. No further testing was required and the substance did not meet the criteria for a flammable solid.

Description of key information

The flammability of the test item 6FDA was determined according to EU Method A.10.  The test item melted in contact with the ignition source.  A localised small to medium orange flame was produced, there was no further propagation. No further testing was required and the substance did not meet the criteria for a flammable solid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test item melted in contact with the ignition source.  A localised small to medium orange flame was produced, there was no further propagation. No further testing was required and the substance did not meet the criteria for a flammable solid.