Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Mass median aerodynamic diameter:
145.86 µm
Key result
Percentile:
D90
Mean:
289.5 µm
Remarks on result:
other: St. dev. not given in the study report
Key result
Percentile:
D50
Mean:
145.86 µm
Remarks on result:
other: St. dev. not given in the study report
Key result
Percentile:
D10
Mean:
39.2 µm
Remarks on result:
other: St. dev. not given in the study report
Conclusions:
The test item was determined to have values of 39.20, 145.86 and 289.50 µm, for D10, D50 and D90, respectively.

Description of key information

Myclobutanil was determined to have values of 39.20, 145.86 and 289.50 µm, for D10, D50 and D90, respectively.

Additional information