Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 8, 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 100 °C
Atm. press.:
760 Torr

Three replicates were performed.  During each replicate, the substance boiled without ignition.


 


The flash point for each replicate was as follows:


Replicate 1: >100.1 degrees C


Replicate 2: >100.0 degrees C


Replicate 3: >100.1 degrees C

Interpretation of results:
GHS criteria not met
Conclusions:
The substance boiled without ignition. The flash point is therefore >100 degrees C.
Executive summary:

The flash point of the substance was determined in an OPPTS 830.6315 test.  Three replicates were performed.  In each case the substance boiled without ignition.  The flash point is therefore >100 degrees C.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion