Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
other: Gallenkamp flashpoint device (autoflash AF3)

Test material

Constituent 1
Reference substance name:
Low molecular weight organic substances from fast pyrolysis bio-oil
IUPAC Name:
Low molecular weight organic substances from fast pyrolysis bio-oil
Constituent 2
Reference substance name:
Monomers from fast pyrolysis bio-oil
IUPAC Name:
Monomers from fast pyrolysis bio-oil
Constituent 3
Reference substance name:
Dimers from fast pyrolysis bio-oil
IUPAC Name:
Dimers from fast pyrolysis bio-oil
Constituent 4
Reference substance name:
Trimers from fast pyrolysis bio-oil
IUPAC Name:
Trimers from fast pyrolysis bio-oil
Constituent 5
Reference substance name:
Higher oligomers from fast pyrolysis bio-oil
IUPAC Name:
Higher oligomers from fast pyrolysis bio-oil
Constituent 6
Chemical structure
Reference substance name:
Water
EC Number:
231-791-2
EC Name:
Water
Cas Number:
7732-18-5
Molecular formula:
H2O
IUPAC Name:
water
Test material form:
liquid: viscous
Remarks:
Brown /black highly vicous liquid

Results and discussion

Flash point
Key result
Flash point:
> 100 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: After reaching 100°C the analysis had to be stopped due to boiling of residual water in the Pyrolytic Lignin

Any other information on results incl. tables

Replicate Flashpoint (°C)
1 > 100
2 > 100
3 > 100

The measurement was stopped at 100°C due to boiling of residual water on the test item.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The average flashpoint of Pyrolytic Lignin was >100°C. The measurement was stopped at 100°C due to boiling of residual water on the test item.
Executive summary:

The report describes the analysis of te flashpoint (FP) and density of Pyrolytic Lignin. The flashpoint analysis was performed with a Gallenkamp flashpoint device (autoflash AF3) using a closed cup system accordingto ASTM D93 -IP34. The average result of the flashpoint for Pyrolytic Lignin was >100 °C.