Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC estimation method
Test temperature:
20°C
Details on study design: HPLC method:
Test item is a UVCB, the HPLC method was therefore performed at neutral pH. Solutions of the test item was analyzed.
Computational methods:
The pKa values of the test item were calculated using the Perrin calculation method (pKalc 5.0, module in Pallas 3.0, CompuDrug International San Francisco, CA, USA).
Type:
log Koc
Value:
> 5.63 dimensionless
pH:
7
Remarks on result:
other: corresponds with a Koc of 4.3E5
Details on results (HPLC method):
The test item could not be eluted from the column standardly used in the study (Acquity UPLC HSS Cyano) applying 100% methanol at 0.4 mL/min flow after 2 hours. Injecting the test item solution without a column for detection with refractive index detector was also not possible due to the intense response of the solvent. During method validation test item was successfully eluted from the column only after 13 minutes when Acquity UPLC BEH C8 column was used with flow 0.6 mL/min. Therefore it can be assumed that test item would elute after 4,4’-DDT (log Koc 5.63).
Validity criteria fulfilled:
yes
Conclusions:
The log Koc of the test item was >5.63.
Executive summary:

The adsorption/desorption coefficient of the test item was determined. The principle of the test method is similar to that of the OECD Guideline 117: "Partition coefficient (n-octanol/water), high performance liquid chromatography (HPLC) method". The test item is a UVCB, the HPLC method was therefore performed at neutral pH.The adsorption coefficient (Koc) of the test item at 20°C was estimated to be > 4.3E5, whichcorresponds with a log Koc value of > 5.63.

Description of key information

Key value for chemical safety assessment

Koc at 20 °C:
430 000

Additional information