Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because exposure of humans via inhalation is not likely taking into account the vapour pressure of the substance and/or the possibility of exposure to aerosols, particles or droplets of an inhalable size
Justification for type of information:
The substance has low vapour pressure
Although supplied in water and used in liquid form, there is a low risk of aerosol formation during normal use as a corrosion inhibitor in closed systems.
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Justification for type of information:
Although done to a recognised screening test method, the nature of this UVCB substance means that only the the most volatile constuent will have been measured; in the case of this reaction product, it is likely that unreacted starting materials may contribute to the findings.
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
Dynamic method
GLP compliance:
no
Type of method:
effusion method: isothermal thermogravimetry
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
ca. 644 Pa

Use of ebulliometer, with the temperature stabilised at 107 C. Calculated back for 20 C

Conclusions:
Although done to a recognised screening test method, the nature of this UVCB substance means that only the the most volatile constuent will have been measured; in the case of this reaction product, it is likely that low molecular weight components will contribute to the findings. However, the smallest identified component has an estimated vapour pressure of < 10 Pa.

Although it was attempted to remove water, the 'dried' sample will have residual residual water and this is th emost likely reason for the higher than expected vapour pressure.

A very large proportion of the components have molecular weights in excess of 200 and a review of vapour pressure data suggests < 0.1 Pa can be expected; however, the same modelling and assessment suggest that the product should be solid (this makes the presence of significant levels of water or liquid amines acting as solvent).

A figure of 644 Pa is considered high for the CSR and a more conservative figure of 1 Pa is used.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion