Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5 May 2017 to 14 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
GLP compliance:
yes
Type of method:
spinning rotor
Key result
Test no.:
#1
Temp.:
10 °C
Vapour pressure:
0.004 Pa
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.002 Pa
Key result
Test no.:
#1
Temp.:
30 °C
Vapour pressure:
0.002 Pa

Background Vapor Pressure and System Out-Gassing Rate Measurements at 10 °C, 20 °C and 30°C ± 1 °C

Using Air Parameters

Temperature (°C) Measured vapor pressure (pa) Min/Max Temperature (°C) Mean
Measured
Vapor Pressure
(Pa)
Standard
Deviation
(Pa)
Coefficient
of Variation
(CV)
10 8.95 E-06 9.9/10.0 4.74 x 10-6 1.1 E-05 230%
1.29 E-05 9.9/10.0
-7.62 E-06 9.8/9.9
20 1.36 E-05 20.0/20.1 2.94 x 10-6 1.3 E-05 443%
6.83 E-06 20.0/20.1
-1.16 E-05 20.0/20.1
30 1.68 E-05 29.6/30.2 2.19 x 10-5 1.9 E-05 85%
4.25 E-05 29.6/30.2
6.27 E-06 29.6/30.2

Temperature (°C) Measured Out-gassing Rate (Pa/s) Min/Max
Temperature
(°C)
Mean
Measured
Out-gassing Rate
(Pa/s)
Standard
Deviation
(Pa/s)
10 7.28 E-08 9.9/10.0 6.27 E-08 1.5 E-08
7.02 E-08 9.9/10.0
4.52 E-08 9.8/9.9
20 4.79 E-07 20.0/20.1 4.81 E-07 3.5 E-09
4.79 E-07 20.0/20.1
4.85 E-07 20.0/20.1
30 6.29 E-07 29.6/30.2 6.26 E-07 1.0 E-08
6.14 E-07 29.6/30.2
6.34 E-07 29.6/30.2
Conclusions:
The mean measured vapor pressure of the test substance by the SRG was 3.97 E-03 Pa (N = 3, CV = 20%) at 10 °C, 1.90 E-03 Pa (N = 3, CV = 14%) at 20 °C and 2.26 E-03 Pa (N = 3, CV = 18%) at 30 °C.
Executive summary:

The vapor pressure of the test substance was determined at three temperatures, 10 °C, 20 °C and 30 °C using the spinning rotor gauge method. The mean measured vapor pressure of the test substance by the SRG was 3.97E-03 Pa (N = 3, CV = 20%) at 10 °C, 1.90E-03 Pa (N = 3, CV = 14%) at 20 °C and 2.26E-03 Pa (N = 3, CV = 18%) at 30 °C. The change in vapor pressure between each temperature condition was within the expected reproducibility variation of the SRG method for a UVCB therefore test substance was determined to have a constant vapor pressure within the range of temperatures investigated (i.e. 10 °C to 30 °C).

Description of key information

The mean measured vapor pressure of the test substance by the SRG was 3.97 x 10 -3 Pa (N = 3, CV = 20%) at 10°C, 1.90 x 10-3 Pa (N = 3, CV = 14%) at 20°C and 2.26 x 10-3 Pa (N = 3, CV = 18%) at 30°C.

Key value for chemical safety assessment

Vapour pressure:
0.002 Pa
at the temperature of:
20 °C

Additional information