Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
69 °C
Atm. press.:
ca. 1 atm

automated PMCC;

Procedure C;

ignition source: hot wire

   1st test  2nd test  Average
 Flash point (°C)  69.5 68.5   69
Interpretation of results:
GHS criteria not met
Conclusions:
The substance shows a Flash point of 69°C at 1 atm.
Executive summary:

The substance Hydrocarbons, C10-C12, n-alkanes, <2% aromatics shows a Flash Point of 69°C at 1 atm. measured with ASTM D93.

Endpoint:
flash point of flammable liquids
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with ASTM D 93-07 testing method however not conducted under GLP.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 93-07
Deviations:
no
GLP compliance:
no
Remarks:
Not specified
Type of method:
other: Pensky-Martens closed cup
Key result
Flash point:
79 °C
Atm. press.:
1 atm
Conclusions:
The measured flash point is 79°C at 1 atm.
Executive summary:

The flash point of the substance Hydrocarbons, C10-C13, n-alkanes, <2% aromatics has been measured at 79°C at 1 atm according to the ASTM D 93-07 method.

Description of key information

The substance Hydrocarbons, C10-C12, n-alkanes, <2% aromatics shows a Flash Point of 69°C at 1 atm. measured with ASTM D93.

The flash point of the substance Hydrocarbons, C10-C13, n-alkanes, <2% aromatics, obtained in accordance with ASTM D 93-07 testing method, is higher than 61°C at 1 atm.

This data is used for read across to Hydrocarbons, C10-C12, n-alkanes, <2% aromatics.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
69 °C

Additional information