Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 283-585-7 | CAS number: 84682-23-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Skin irritation:
In a K2 in vivo skin irritation study in New Zealand White rabbits according to the OECD guideline N°404 and the EU Method B.4, no evidence for skin irritation was noted for T001159.
Eye irritation:
In a K1 Bovine Corneal Opacity and Permeability (BCOP) test, performed according to OECD guideline 437 and EU method B.47, T001159 did not induce occular irritation. No classification is required for eye irritation or serious eye damage.
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2005-04-07 to 2005-04-10
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Remarks:
- Non-GLP study according to OECD guideline 404 and EU Method B.4
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 404 (Acute Dermal Irritation / Corrosion)
- Deviations:
- yes
- Remarks:
- Inadequate documentation
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.4 (Acute Toxicity: Dermal Irritation / Corrosion)
- Deviations:
- yes
- Remarks:
- Inadequate documentation
- GLP compliance:
- no
- Remarks:
- The study was conducted in a facility operating to Good Laboratory Practice within the UK national GLP monitoring programme. No formal claim of GLP compliance is made for the study.
- Specific details on test material used for the study:
- No data
- Species:
- rabbit
- Strain:
- New Zealand White
- Details on test animals or test system and environmental conditions:
- TEST ANIMALS: no data
ENVIRONMENTAL CONDITIONS: no data
IN-LIFE DATES: no data - Type of coverage:
- semiocclusive
- Preparation of test site:
- not specified
- Vehicle:
- not specified
- Controls:
- not specified
- Amount / concentration applied:
- 0.5 g
- Duration of treatment / exposure:
- 4 hours
- Observation period:
- 72 hours, with observations at 1, 24, 48, and 72 hours
- Number of animals:
- 3
- Details on study design:
- TEST SITE: no data
REMOVAL OF TEST SUBSTANCE: no data
SCORING SYSTEM:
Draize System 0-4
From Draize J H (1959) “Dermal Toxicity” in Appraisal of the Safety of Chemicals in Foods, Drugs and Cosmetics. Assoc. of Food and Drug Officials of the US, Austin, Texas p47 - Irritation parameter:
- primary dermal irritation index (PDII)
- Basis:
- mean
- Time point:
- 72 h
- Score:
- 0
- Max. score:
- 8
- Remarks on result:
- other: Non-irritant
- Irritation parameter:
- erythema score
- Basis:
- mean
- Remarks:
- animal 46
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritation parameter:
- erythema score
- Basis:
- mean
- Remarks:
- animal 48
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritation parameter:
- erythema score
- Basis:
- mean
- Remarks:
- animal 49
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritation parameter:
- edema score
- Basis:
- mean
- Remarks:
- animal 46
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritation parameter:
- edema score
- Basis:
- mean
- Remarks:
- animal 48
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritation parameter:
- edema score
- Basis:
- mean
- Remarks:
- animal 49
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritant / corrosive response data:
- No evidence of skin irritation was noted at any time at any test site.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test substance was found to be non-irritant to rabbit skin.
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 2015-06-22 to 2015-06-23
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
- Deviations:
- no
- Principles of method if other than guideline:
- The study procedures described in the study are also in compliance with the following documents:
- The Ocular Toxicity Working Group (OTWG) of the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) and the National Interagency Centre for the Evaluation of Alternative Toxicological Methods (NICEATM), Background Review Document (BRD): current status of in vitro test methods for identifying ocular corrosives and severe irritants: The Bovine Corneal Opacity and Permeability (BCOP) Test Method, March 2006.
- In Vitro Techniques in Toxicology Database (INVITTOX) protocol 127. Bovine Opacity and Permeability (BCOP) Assay, 2006.
- Gautheron P, Dukic M, Alix D and Sina J F, Bovine corneal opacity and permeability test: An in vitro assay of ocular irritancy. Fundam Appl Toxicol 18:442-449, 1992. - GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: M14IB5308
- Expiration date of the lot/batch: 2015-09-01 (retest date)
- Purity test date: no data
- Certificate of analysis release date: 2015-04-23
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
- Stability under test conditions: no data
- Solubility and stability of the test substance in the solvent/vehicle: no data
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: no data
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: A 20% (w/v) suspension of the test item was prepared in physiological saline. The suspension was treated with ultrasonic waves. - Species:
- other: bovine eyes
- Strain:
- other: not applicable
- Details on test animals or tissues and environmental conditions:
- TEST SYSTEM
- Source: bovine eyes from young cattle were obtained from the slaughterhouse (Vitelco, -'s Hertogenbosch, The Netherlands), where the eyes were excised by a slaughterhouse employee as soon as possible after slaughter. Bovine eyes were used as soon as possible but within 4 hours after slaughter. Eyes were collected and transported in physiological saline in a suitable container under cooled conditions.
- Preparation of corneas: the eyes were checked for unacceptable defects, such as opacity, scratches, pigmentation and neovascularization by removing them from the physiological saline and holding them in the light. Those exhibiting defects were discarded.
The isolated corneas were stored in a petri dish with cMEM (Eagle’s Minimum Essential Medium (Life Technologies, Bleiswijk, The Netherlands) containing 1% (v/v) L-glutamine (Life Technologies) and 1% (v/v) Foetal Bovine Serum (Life Technologies)). The isolated corneas were mounted in a corneal holder (one cornea per holder) of MC2 (Clermont-Ferrand, France) with the endothelial side against the O-ring of the posterior half of the holder. The anterior half of the holder was positioned on top of the cornea and tightened with screws. The compartments of the corneal holder were filled with cMEM of 32 ± 1°C. The corneas were incubated for the minimum of 1 hour at 32 ± 1°C.
- Cornea selection and opacity reading: after the incubation period, the medium was removed from both compartments and replaced with fresh cMEM. Opacity determinations were performed on each of the corneas using an opacitometer (OP-KIT, MC2, Clermont-Ferrand, France). The opacity of each cornea was read against an air filled chamber, and the initial opacity reading thus determined was recorded. Corneas that had an initial opacity reading higher than 3 were not used. Three corneas were selected at random for each treatment group. - Vehicle:
- physiological saline
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 750 µL
- Concentration: 20% (w/v) in physiological saline
VEHICLE
- Amount applied: 750 µL
POSITIVE CONTROL
- Amount applied: 750 µL
- Concentration: 20% (w/v) imidazole solution - Duration of treatment / exposure:
- Corneas were incubated for 240 ± 10 minutes at 32 ± 1°C.
- Observation period (in vivo):
- After 240 ± 10 minutes of treatment, opacity was measured with an opacitometer. The permeability measurement of the corneas was performed after the incubation period of 90 minutes ± 5 minutes following the opacity measurement.
- Number of animals or in vitro replicates:
- Three corneas were selected at random for each treatment group.
- Details on study design:
- CORNEA SELECTION AND OPACITY READING
After the incubation period, the medium was removed from both compartments and replaced with fresh cMEM. Opacity determinations were performed on each of the corneas using an opacitometer (OP-KIT, MC2, Clermont-Ferrand, France). The opacity of each cornea was read against an air filled chamber, and the initial opacity reading thus determined was recorded. Corneas that had an initial opacity reading higher than 3 were not used. Three corneas were selected at random for each treatment group.
TREATMENT OF CORNEAS
The medium from the anterior compartment was removed and 750 μL of either the negative control, positive control (20% (w/v) Imidazole solution) or 20% (w/v) test item was introduced onto the epithelium of the cornea. The holder was slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the solutions over the entire cornea. Corneas were incubated in a horizontal position for 240 ± 10 minutes at 32 ± 1°C. After the incubation the solutions were removed and the epithelium was washed at least three times with MEM with phenol red (Eagle’s Minimum Essential Medium Life Technologies). Possible pH effects of the test item on the corneas were recorded. Each cornea was inspected visually for dissimilar opacity patterns. The medium in the posterior compartment was removed and both compartments were refilled with fresh cMEM and the opacity determinations were performed.
OPACITY MEASUREMENT
The opacitometer determined the difference in the light transmission between each control or treated cornea and an air filled chamber. The numerical opacity value (arbitrary unit) was displayed and recorded. The change in opacity for each individual cornea (including the negative control) was calculated by subtracting the initial opacity reading from the final post-treatment reading. The corrected opacity for each positive control or test item treated cornea was calculated by subtracting the average change in opacity of the negative control corneas from the change in opacity of each positive control or test item treated cornea.
The mean opacity value of each treatment group was calculated by averaging the corrected opacity values of the treated corneas for each treatment group.
APPLICATION OF SODIUM FLUORESCEIN
Following the final opacity measurement, permeability of the cornea to Na-fluorescein (Merck) was evaluated.
The medium of both compartments (anterior compartment first) was removed. The posterior compartment was refilled with fresh cMEM. The anterior compartment was filled with 1 mL of 5 mg Na-fluorescein/mL cMEM solution (Sigma-Aldrich Chemie GmbH, Germany). The holders were slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the sodium-fluorescein solution over the entire cornea. Corneas were incubated in a horizontal position for 90 ± 5 minutes at 32 ± 1°C.
PERMEABILITY DETERMINATIONS
After the incubation period, the medium in the posterior compartment of each holder was removed and placed into a sampling tube labelled according to holder number. 360 μl of the medium from each sampling tube was transferred to a 96-well plate. The optical density at 490 nm (OD490) of each sampling tube was measured in triplicate using a microplate reader (TECAN Infinite® M200 Pro Plate Reader). Any OD490 that was 1.500 or higher was diluted to bring the OD490 into the acceptable range (linearity up to OD490 of 1.500 was verified before the start of the experiment). OD490 values of less than 1.500 were used in the permeability calculation.
The mean OD490 for each treatment was calculated using cMEM corrected OD490 values. If a dilution was performed, the OD490 of each reading was corrected for the mean negative control OD490 before the dilution factor was applied to the readings.
INTERPRETATION
The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:
In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value)
Additionally the opacity and permeability values were evaluated independently to determine whether the test item induced irritation through only one of the two endpoints.
The IVIS cut-off values for identifying the test items as inducing serious eye damage (UN GHS Category 1) and test items not requiring classification for eye irritation or serious eye damage (UN GHS No Category) are given hereafter:
In vitro score range UN GHS
≤ 3 No Category
> 3; ≤ 55 No prediction can be made
>55 Category 1 - Irritation parameter:
- in vitro irritation score
- Run / experiment:
- test item after 240 minutes of treatment
- Value:
- -0.2
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Remarks:
- test item IVIS range: -1.6 to 1.4
- Irritation parameter:
- cornea opacity score
- Run / experiment:
- test item after 240 minutes of treatment
- Value:
- 0
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: test item opacity range: -1.3 to 1.7
- Irritation parameter:
- other: cornea permeability score
- Run / experiment:
- test item after 240 minutes of treatment
- Value:
- -0.014
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: test item permeability score range: -0.017 to 0.012
- Other effects / acceptance of results:
- The corneas treated with the positive control were turbid after the 240 minutes of treatment. Two corneas were clear and one cornea was flecked on the edge after the 240 minutes of treatment with the test item. No pH effect of the test item was observed on the rinsing medium.
NEGATIVE CONTROL:
mean in vitro irritancy score (range): 0.0 (-0.4 to 0.5)
mean opacity scores (range): 0.0 (-0.3 to 0.7)
mean permeability scores (range): 0.000 (-0.011 to 0.017)
POSITIVE CONTROL:
mean in vitro irritancy score (range): 153.9 ( 151.3 to 158.8)
mean opacity scores (range): 106.0 (92.7 to 115.7)
mean permeability scores (range): 3.195 (2.373 to 3.935)
- The negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas.
- The mean in vitro irritancy score of the positive control (20% (w/v) Imidazole) was within the historical positive control data range. Furthermore the opacity and permeability values of the positive control were within two standard deviations of the current historical mean.
- It was therefore concluded that test conditions were adequate and that the test system functioned properly.
Interpretation:
The IVIS of all replicates was within one category. - Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test item did not induce ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of -0.2 (-1.6 to 1.4) after 240 minutes of treatment.
Since the test item induced an IVIS ≤ 3, no classification is required for eye irritation or serious eye damage.
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Skin irritation
Sanders (2005) investigated acute dermal irritation of T001159 in New Zealand White rabbits (3 males after 4 hours of exposure to 0.5 g of test item). Skin reactions were recorded 1, 24, 48 and 72 hours after administration and scored according to the Draize scale.
There were no signs of irritation for any animal during the 72-hour observation period the following the 4-hour exposure period. The test item did not meet the criteria for classification as irritant or corrosive according to EU labelling regulations Commission Directive 2001/59/EC.
An in vitro skin irritation study was waived based on the justification that adequate data from an in vivo skin irritation study are available.
Eye irritation
Eurlings (2015) investigated eye irritation in an in vitro bovine corneal opacity-permeability (BCOP) assay. 750 µl of a 20% (w/v) suspension of the test item was applied on the top of 3 corneas for 240 minutes. Both opacity and permeability were measured and the resulting objective values were combined in an empirically derived formula to generate an In Vitro Irritancy Score (IVIS). The corneas treated with T001159 were clear after 240 minutes of treatment. The test item did not induce ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of -0.2 (-1.6 to 1.4). Since the test item induced an IVIS ≤ 3, no classification is required for eye irritation or serious eye damage.
In addition, a rabbit enucleated eye test (REET) was performed by Sanders (2005) to assess the ocuar irritancy potential of T001159. Three enucleated eyes, obtained from the New Zealand White strain of rabbit, were treated with 0.1 ml of T001159 (approx 74 mg). Corneal opacity (60, 120, 180 and 240 minutes after application), corneal swelling (60, 120 and 240 minutes after application) and fluorescein uptake (240 minutes after application) were observed and scored.
The test item had no effect on corneal opacity and corneal epithelium condition at any time. There was no fluorescein uptake by any eye at any time observed, and only minimal corneal swelling (7.1 - 10.5%). The test item was not considered to have the potential to cause severe occular irritancy in vivo.
The BCOP study is considered the key result for assessing the eye irritation endpoint. According to Chapter R.7a: Endpoint specific guidance Version 5.0 - December 2016 (R.7.2.11.2), data obtained from non-validated suitable in vitro tests can only be used according to the criteria set out in section 1.4 of Annex XI to the REACH Regulation, i.e. only positive results can be accepted in a weight of evidence approach. As the result of the non-validated REET test was negative, this study was added to the dossier as supporting evidence and the newly conducted and validated BCOP study is selected as key study for classification purposes.
Justification for classification or non-classification
Skin irritation:
According to the in vivo acute dermal irritation study no evidence for skin irritation was noted for T001159. The test item did not meet the criteria for classification as irritant or corrosive according to the criteria of the CLP regulation (EC) No 1272/2008.
Eye irritation:
According to the in Bovine Corneal Opacity and Permeabilty (BCOP) test, T001159 induced no ocular irritation. The test item did not meet the criteria for classification and no classification is required for eye irritation of serious eye damage according to the criteria of the CLP regulation (EC) No 1272/2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.