Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
adsorption / desorption, other
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACh Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method
Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method
- Water solubility: 59.4 mg/L
Type:
Koc
Value:
4 516 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
3.655 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Endpoint:
adsorption / desorption, other
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method
Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method
- Water solubility: 59.4 mg/L
- Vapour pressure: 3.14E-4 Pa at 25 °C (OECD 104 and A.4.)
Type:
Koc
Value:
2 887 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
3.461 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Endpoint:
adsorption / desorption, other
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method
Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method
- Water solubility: 59.4 mg/L

Type:
Koc
Value:
1 846 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
3.266 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Endpoint:
adsorption / desorption, other
Remarks:
adsorption
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Remarks:
The substance is not fully compliant with the applicability domain of the model. However, this calculation is used in a weight of evidence approach, in accordance to the REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2. It is adequately documented and justified: the prediction is evaluated on the basis of the model performance on similar substances. For more details see section `overall remarks, attachments´.
Justification for type of information:
1. SOFTWARE
EPI Suite v4.11 Estimation Programs Interface Suite™ for Microsoft® Windows v 4.11. US EPA, United States Environmental Protection Agency, Washington, DC, USA.

2. MODEL (incl. version number)
KOCWIN v2.00

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: KOCWIN v2.00, MCI based method

Full reference and details of the used formulas can be found in:
Meylan, W., P.H. Howard and R.S. Boethling, "Molecular Topology/Fragment Contribution Method for Predicting Soil Sorption Coefficients", Environ. Sci. Technol. 26: 1560-7 (1992)

- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: calculation
Media:
soil
Details on test conditions:
BASIS FOR CALCULATION OF Koc:
- Estimation software: EPI Suite™ v 4.11, KOCWIN v2.00, MCI based method
- Water solubility: 59.4 mg/L
- Vapour pressure: 3.14E-4 Pa at 25 °C (OECD 104 and A.4.)
Type:
Koc
Value:
10 000 000 000 L/kg
Temp.:
25 °C
Type:
log Koc
Value:
11.639 dimensionless
Temp.:
25 °C

For detailed information on the results please refer to the attached report.

Description of key information

log Koc = 3.266 – 11.6388 (constituents 1 - 4, KOCWIN v2.00, MCI)

Key value for chemical safety assessment

Koc at 20 °C:
1 846

Additional information

There is no experimental study available, in which the adsorption coefficient of the substance was assessed. Therefore, the adsorption coefficient was calculated by (Q)SAR, using the MCI method of the KOCWIN v2.00 model (EPI Suite v4.11).

Since the substance is a UVCB, the adsorption coefficient was estimated for the four main constituents of the substance. The experimental log Pow of 3.35 and 3.76 (OECD 117) is available, which was measured for the two UV active main components. Therefore the test item has two log Pow coefficients at 20 °C, 3.35 and 3.76. Due to the fact that these values could not be allocated to the four constituents, only the water solubility values were included as input parameter for the estimation.

Not all components fall completely within the applicability domain of the method and thus the reported results are not fully reliable but may serve as an indication of possible trends. The results are used in a weight of evidence approach in accordance with REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2.

The estimated log Koc values of the four representative components range from 3.65 to 11.6388 (based on the MCI method). Thus, the substance has the potential to adsorb to sediment and soil particles.