Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: ASTM test method, non-GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D445
Principles of method if other than guideline:
The time is measured for a fixed volume of liquid to flow through the capillary viscometer under an accurately reproducible head and at a closely controlled temperature. The kinematic viscosity is then calculated from the measured flow time and the calibration constant of the viscometer.
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
(6E)-2,6-dimethyl-10-methylidenedodeca-2,6-diene; (6E)-3,7,11-trimethyldodeca-1,6,10-triene; (6E,10E)-2,6,10-trimethyldodeca-2,6,10-triene; (6E,10Z)-2,6,10-trimethyldodeca-2,6,10-triene
EC Number:
942-471-3
Cas Number:
1581740-29-5
Molecular formula:
C15H26
IUPAC Name:
(6E)-2,6-dimethyl-10-methylidenedodeca-2,6-diene; (6E)-3,7,11-trimethyldodeca-1,6,10-triene; (6E,10E)-2,6,10-trimethyldodeca-2,6,10-triene; (6E,10Z)-2,6,10-trimethyldodeca-2,6,10-triene
Test material form:
other: liquid
Details on test material:
Batch: RV-650-70-2
Sample ID: 2012-SANF-000190-028

Results and discussion

Viscosity
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 1.853

Applicant's summary and conclusion

Conclusions:
Kinematic viscosity = 1.853 mm2/sec at 40C