Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-835-0 | CAS number: 7758-16-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- The samples were drawn through a Sierra 218 cascade impactor at 2.78 liters per minute. The aerodynamic particle size distribution was determined by gravimetric analysis of the amount of test material collected on the impactor stages and subsequent determination of the mass median aerodynamic diameter (MMAD), geometric standard deviation and other particle size parameters by logarithmic-probability plotting.
- GLP compliance:
- yes
- Type of method:
- cascade impaction
- Type of distribution:
- counted distribution
- Percentile:
- D50
- Mean:
- > 4.61 - < 4.87 µm
- Remarks on result:
- other: with geometric standard deviations ranging from 2.98 to 3.39(migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.)
- Conclusions:
- The MMAD represents the smallest size that could be achieved in this study. The material is hygroscopic causing the particles to agglomerate and/or adhere to surfaces inside the chamber.
The substance tested is considered to pose an inhalation risk and be respirable in size to the rat. This study is conducted according to the appropriate method and under the conditions of GLP and therefore the study is considered to be acceptable and to adequately satisfy both the guideline requirement and the regulatory requirement as a key study for this endpoint.
Reference
The MMAD represents the smallest size that could be achieved in this study. The material is hygroscopic causing the particles to agglomerate and/or adhere to surfaces inside the chamber. Several trials were initially performed with various generation schemes and the system which was ultimately chosen provided the best performance.
- Particle size distribution: The fraction of particles less than or equal to 1 µm in mass aerodynamic diameter, based on the log-probability graphs, ranged from 7.6 to 9.4%. The fraction of particles less than or equal to 10 µm in mass aerodynamic diameter, based on the log probability graphs, ranged from 72.3 to 76.1%. These results indicated the test material was respirable in size to the rat.
Description of key information
The data concludes that disodium dihydrogenpyrophosphate presents an inhalation risk.
Additional information
The MMAD (>4.61 < 4.87 µm) represents the smallest size that could be achieved in this study. The material is hygroscopic causing the particles to agglomerate and/or adhere to surfaces inside the chamber.
Particle size distribution: The fraction of particles less than or equal to 1 µm in mass aerodynamic diameter, based on the log-probability graphs, ranged from 7.6 to 9.4%. The fraction of particles less than or equal to 10 µm in mass aerodynamic diameter, based on the log probability graphs, ranged from 72.3 to 76.1%. These results indicated the test material was respirable in size to the rat.
In addition, data provided by registrants supports the assertion that disodium dihydrogenpyrophosphate is inhalable (>90% of particles were <100 µm)
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.