Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method

Test material

Constituent 1
Chemical structure
Reference substance name:
2-tetradecyloxirane, reaction products with boric acid
EC Number:
701-392-2
IUPAC Name:
2-tetradecyloxirane, reaction products with boric acid
Details on test material:
- Physical state: Waxy off-white solid
- Analytical purity: Not applicable - complex mixture
- Lot/batch No.: 0101033612
- Stability under test conditions: Normally stable at moderately elevated temperatures and pressures
- Storage condition of test material: Room temperature in the dark
Radiolabelling:
no

Study design

HPLC method

Details on study design: HPLC method:
The sample, dead time and reference standard solutions were injected in duplicate using the following HPLC parameters:

HPLC System Agilent Technologies 1050, incorporating autosampler, workstation and Polymer Laboratories Evaporative Light Scattering Detector 2100 (ELSD)
Column Xselect HSS cyano 5 µm (150 x 4.6 mm id)
Column temperature 30 °C
Mobile phase Methanol:water (55:45 v/v)
pH of mobile phase 5.3
Flow-rate 1.0 mL/min
Injection volume 10 µL
UV detector wavelength dead time and reference standards: 210 nm
Detector (ELSD) parameters Nebuliser temperature: 70°C
Evaporative temperature: 80°C
Gas flow: 1.0 SLM

Results and discussion

Adsorption coefficientopen allclose all
Key result
Type:
Koc
Value:
> 427 000 dimensionless
pH:
5.8
Temp.:
30 °C
Key result
Type:
log Koc
Value:
> 5.63 dimensionless
pH:
5.8
Temp.:
30 °C

Results: Batch equilibrium or other method

Transformation products:
not measured

Any other information on results incl. tables

Table showing the retention times of the standards

 

Standard

RetentionTime(mins)

MeanRetentionTime(mins)

CapacityFactor(k)

 

Log10k

 

Log10Koc

Injection1

Injection2

Acetanilide

2.766

2.761

2.764

0.418

-0.379

1.25

Phenol

2.639

2.639

2.639

0.354

-0.451

1.32

Atrazine

3.899

3.906

3.903

1.00

7.79X10-4

1.81

Isoproturon

4.248

4.265

4.257

1.18

7.31X10-2

1.86

Linuron

6.220

6.266

6.243

2.20

0.343

2.59

Naphthalene

5.226

5.233

5.230

1.68

0.226

2.75

Endosulfan-diol

8.127

8.076

8.102

3.16

0.499

3.02

Fenthion

9.845

9.765

9.805

4.03

0.605

3.31

alpha-endosulfan

14.476

14.425

14.451

6.41

0.807

4.09

Phenanthrene

10.524

10.592

10.558

4.42

0.645

4.09

Diclofop-methyl

15.577

15.614

15.596

7.00

0.845

4.20

DDT

32.935

33.100

33.018

15.9

1.20

5.63

Retention time for test item

Injection

RetentionTime(mins)

CapacityFactor(k')

Log10k'

Log10K00

MeanLog10Koc

AdsorptionCoefficient

1

39.680

>15.936

>1.202

>5.63

 

>5.63

 

>4.27X105

 

2

 

39.680

 

>15.936

 

>1.202

 

>5.63


Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Executive summary:

The adsorption coefficient was performed using the HPLC screening method according to OECD Guideline 121 and EC Method C.19.

The test item had no dissociation constants within the environmentally relevant pH range and therefore was tested in an unadjusted mobile phase. The sample was prepared in tetrahydrofuran that had been shaken with anhydrous sodium sulphate in an attempt to remove residual water and reduce any potential hydrolysis that may occur while in solution prior to analysis.

The adsorption coefficient (Koc) of the test item has been determined to be > 4.27E05, Log Koc > 5.63.

[LogKoc: 5.63]