Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Data ia from experimental study report
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
76 °C
Atm. press.:
977.8 hPa

Type of method

·    Closed cup

 

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky – Martin’s flash point apparatus

Pensky – Martin’s flash point apparatus

Volume of chemical used

ml

10 ml

Ignition source

Gas lighter/flame

Gas lighter

Atmospheric pressure

hPa

977.8 hPa

Flash point (RESULT)

°C

76 °C

Interpretation of results:
other: non flammable
Conclusions:
The flash point of test chemical was determined to be 76 °C at 977.8 hPa.
Executive summary:

The flash point determination of test chemical was done by closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test chemical was determined to be 76 °C at 977.8 hPa.

Description of key information

The flash point determination of test chemical was done by closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test chemical was determined to be 76 °C at 977.8 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
76 °C

Additional information

The flash point determination of test chemical was done by closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test chemical was determined to be 76 °C at 977.8 hPa.