First-aid measures

Emergency measure - Inhalation: Symptomatic treatment. Seek medical advice.

Emergency measure - Eyes: Rinse immediately with plenty of water. Seek medical advice.

Emergency measure - Skin: Rinse immediately with plenty of soap and water.

Emergency measure - Ingestion: Seek medical advice.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, carbon dioxide and dry powder may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,

nitrogen and hydrogen fluoride gas.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus and full protective

clothing should be worn.

Accidental release measures

Emergency measures in case of spillage: Collect spill by mechanical means (eg. vacuum) and transfer

to suitable labelled, closed containers. Dispose of by

incineration at a suitable facility in accordance with local

regulations.

Handling and storage

Handling: Observe the usual precautions for handling organic

chemicals. Rubber gloves, safety goggles and a respirator

mask with P3 cartridge filter should be worn.

Storage: Store in well closed containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Explosive dust clouds may be formed in air.

Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is possible by dissolving in a

suitable solvent followed by repeated recrystallization.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility. Waste gas

treatment to remove oxides of nitrogen and hydrogen fluoride

gas should be fitted.

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: Recovery from preparations is not possible.

Public at large - Possibility of neutralisation: None known.

Public at large - Possibility of destruction: controlled discharge: The substance will only enter the public domain in the form

of preparations that may be disposed of with normal domestic

waste.