Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Patient(in) an die frische Luft bringen. Künstlich beatmen,

wenn Atmung ausgesetzt hat. Dem Patienten/Der Patientin

ansonsten Sauerstoff verabreichen. Sofort Arzt konsultieren.

"ENGLISH"

Take affected person to fresh air. Give artificial

respiration if the respirations stopped. If not offer

affected person oxigen. Seek immediately medical advice.

Emergency measure - Eyes: Auge sofort mindestens 15 Minuten lang mit fließendem Wasser

spülen. Arzt konsultieren.

"ENGLISH"

Rinse eye immediately for 15 minutes with flowing water.

Seek medical advice.

Emergency measure - Skin: Haut sofort mit Wasser abspülen, und mit Wasser und Seife

spülen. Die gesamte verseuchte Kleidung vor Wiederverwendung

reinigen. Bei auftretender Reizung Arzt konsultieren.

"ENGLISH"

Wash skin immediately with water and soap. Clean spoiled

clothes for re-wearing. If irritations occur seek medical

advice.

Emergency measure - Ingestion: Mund mit Wasser spülen. Sofort Arzt konsultieren. (Wenn

Patient(in) bewußtlos ist, nichts oral verabreichen, sondern

sofort Arzt konsultieren.)

"ENGLISH"

Wash mouth with water. Seek immediately medical advice. (If

affected person is unconscious do not apply anything oral

but seek immediately medical advice.)

Fire-fighting measures

Recommended extinguishing agent: Kohlendioxid, Trockenchemikalie. Kein Wasser benutzen.

"ENGLISH"

Carbon dioxide, dry chemicals. Do not use water.

Product arising from burning: Der Stoff ist brennbar und brennt bei Beteiligung an einem

Feuer, wobei Giftgase (z.B. Kohlenstoffoxide und

Siliziumverbindungen) entstehen.

"ENGLISH"

The substance is combustible and burns under participation

with a fire by which toxic gases (e.g. carbon monoxide and

silicium components) arise.

Product determined by test: N

Protective equipment: Vollständige Schutzkleidung und außenluftunabhängiges

Atemschutzgerät müssen angelegt werden.

"ENGLISH"

Wear complete protection clothing and self-contained

respirator.

Accidental release measures

Emergency measures in case of spillage: Personal aus der unmittelbaren Umgebung evakuieren.

Geeignete persönliche Schutzausrüstung tragen, die - wie im

Abschnitt Handhabung erwähnt - den einschlägigen nationalen

oder internationalen Normen genügt.

Verbreitungen von Lösungen mit einem geeigneten inerten

Material (z.B. Sand oder Erde) absorbieren. Die Verbreitung

sorgfältig in Abfallbehälter übertragen oder einen

geschlossenen Industriestaubsauger einsetzen. Mit

Abfallmaterial gefüllte Behälter müssen auf dieselbe Weise

wie die Originalbehälter gekennzeichnet werden.

Waschrückstände nicht in die Kanalisation einleiten.

Das Recycling von Verbreitungen dieses flüssigen Stoffes ist

nicht praktikabel.

Abfallmaterial im Einklang mit kommunalen Vorschriften durch

Verbrennung entsorgen.

"ENGLISH"

Evacuate personal from the affected area.

Wear suitable personal protective equipment as mentioned

under 2.3.10.

Absorb solutions with suitable inert material (e.g. sand or

soil). Fill in waste container or use a close industrial

vacuum cleaner. Label the waste container in the same way as

the original containers. Let wash residues not enter the

sewage system.

The recycling of liquid spreadings of the substance is not

possible.

The waste material should be incinerated in accordance with

the communal regulations.

Handling and storage

Handling: Der Stoff sollte unter guten gewerbehygienischen Bedingungen

und im Einklang mit sämtlichen kommunalen Vorschriften

gelagert, gehandhabt und verwendet werden, um Exposition an

Augen, Haut und durch Verschlucken zu vermeiden.

Technische Kontrollen sind notwendig, um Exposition an den

Stoff herabzusetzen.

Wenn Exposition nicht verhindert oder hinreichend

kontrolliert werden kann, sollte angemessene persönliche

Schutzausrüstung getragen werden. Derartige Schutzausrüstung

sollte den entsprechenden internationalen oder nationalen

Normen wie folgt entsprechen:

Chemikalienschutzhandschuhe (Butylgummi) nach Norm prEN374

Chemikalienbeständige (nitrilbeschichtete) Kleidung nach

Norm EN368

Augenschutz (Schutzbrille oder Gesichtsschutzschild) nach

Norm prEN166.

Nötigenfalls sollte geeigneter Atemschutz benutzt werden,

z.B. eine Gesichtsmaske gemäß EN405 FFA1.

Lokale Absaugungseinrichtungen sollten benutzt werden.

Augenspüleinrichtungen sollten ebenfalls bereitgestellt

werden.

Die o.g. Normen sollten als Mindestvoraussetzung aufgefaßt

werden.

"ENGLISH"

The substance should be stored, used and handled under good

industrial conditionsand in accordance to all communal

regulations, in order to avoid exposure of eyes, skin and by

digestion.

Technical controlls are necessary to lower the exposure with

the substance.

If exposure could not be avoided or controlled sufficiently

wear suitable personal protective equipment. The protective

equipment should fulfill the following international

standards:

chemical protective gloves (butyl rubber)

chemical resistant clothing (nitril covered)

eye protection (goggles or full face protection)

if necessary used suitable respiration protection e.g. face

mask

Use local ventilation. Supply eye wash stations.

The above mention measures are regarded to be the minimum.

Storage: In einem trockenen, kühlen, dunklen gut gelüfteten Bereich

fern von direkter Sonneneinstrahlung lagern.

Behälter fest verschlossen halten, wenn nicht in Gebrauch,

und von Zündquellen fernhalten.

"ENGLISH"

Store in a dry, cool, dark and well ventilated area

protected from direct sun light.

Keep containers tightly closed if not used any longer and

keep away from ignitions sources.

Packaging of the substance and or preparation: 5 Liter fassende PE-Gefäße. Diese sollten im Einklang mit

kommunalen Vorschriften entsorgt werden.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Die Behälter nicht fallen lassen.

Behälter fest verschlossen halten, wenn nicht in Gebrauch.

"ENGLISH"

Let the containers not fall. Close containers tightly if not
in use.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Sind nicht bekannt. Es wird davon ausgegangen, daß es zu

keiner gefährlichen Polymerisation kommt.

"ENGLISH"

Unknown, it is assumed that there is no dangerous

polymerization.

Chemical reaction with water: Der Stoff ist mit Wasser hydrolysierbar, wobei Ethanol als

Nebenprodukt erzeugt wird.

"ENGLISH"

The substance hydrolysis with water during which ethanol as

byproduct formates.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Rückgewinnung ist weder wirtschaftlich noch technisch

praktikabel, und derartiges Abfallmaterial wird durch

Verbrennung entsorgt.

"ENGLISH"

Recovery is not economically or technially praticable, such

waste material is incinerated.

Industry - Possibility of neutralisation: Nicht möglich

"ENGLISH"

Not possible

Industry - Possibility of destruction: controlled discharge: Kontaminierte Behälter oder Verbreitungen von mit inertem

Material (z.B. Sand oder Erde) gemischten Lösungen können

durch Geländeauffüllung auf einer autorisierten Müllhalde im

Einklang mit kommunalen Vorschriften entsorgt werden.

"ENGLISH"

Contaminated containers or mixtures of inert material (e.g.

sand or soil) with solutions could be disposed via land

filling at a licensed land fill in accordance with the local

regulations.

Industry - Possibility of destruction - incineration: Der Stoff kann durch Verbrennung unter kontrollierten

Bedingungen in einer lizenzierten Abfallverwertungsanlage im

Einklang mit kommunalen Vorschriften entsorgt werden. Abgase

sollten gereinigt werden, weil Giftgase (z.B.

Kohlenstoff- und Siliziumoxide) entstehen könnten.

"ENGLISH"

The substance could be disposed by incineration under

controlled conditions at a licensed inceration plant in

accordance with the local regulation by using flue gas

scrubbing because toxic gases (e.g. carbon- and silicium

oxides) could formate.

Industry - Possibility of destruction - water purification: Der Stoff sollte nicht direkt in die Kanalisation oder den

Wasserhaushalt eingeleitet werden.

"ENGLISH"

The substance should not enter directly the sewage system or

the aquatic environment.

Public at large - Possibility of recovery/recycling: Nicht zutreffend, weil 100 % in der Industrie verwendet

werden.

"ENGLISH"

Inapplicable because 100 % are used in the industry.