Emergency measure - Inhalation: Instructions for Inhalation :

Remove person to fresh air. If signs/symptoms develop, get
medical attention.
Emergency measure - Eyes: Instructions for Eye Contact

Flush eyes with large amounts of water. If signs/symptoms
persist, get medical attention.
Emergency measure - Skin: Instructions for Skin Contact :

Wash affected area with soap and water. If signs/symptoms
develop, get medical attention.
Emergency measure - Ingestion: Instructions for Ingestion :

Do not induce vomiting unless instructed to do so by medical
personnel. Give victim two glasses of water. Never give
anything by mouth to an unconscious person. Get medical
attention.

Fire-fighting measures

Recommended extinguishing agent: Class A extinguishing agents ( water foam ), CO2

Product arising from burning: SiO2 CO2 CO NOx

Product determined by test: N

Protective equipment: wear full protective equipment and a self containing
breathing apparatus

Accidental release measures

Emergency measures in case of spillage: Evacuate unprotected and untrained personnel from hazard
area. The spill should be cleaned up by qualified personnel.
Ventilate the area with fresh air. Contain spill. For
larger spills, cover drains and build dikes to prevent entry
into sewer systems or bodies of water.

Working from around the edges of the spill inward, cover
with bentonite, vermiculite, or commercially available
inorganic absorbent material. Mix in sufficient absorbent
until it appears dry. Clean up

residue with an appropriate solvent selected by a qualified
and authorized person. Ventilate the area with fresh air.
Read and follow safety precautions on the solvent label and
MSDS. Collect the resulting residue containing
solution. Place in a closed container approved for
transportation by appropriate authorities. Dispose of
collected material as soon as possible.

Handling and storage

Handling: Use Instructions :

Avoid eye contact.

Avoid prolonged or repeated skin contact.

Avoid breathing of vapors, mists or spray.

Do not eat, drink or smoke when using this product. Wash
exposed areas thoroughly with soap and water.

Storage: Storage Requirements:

Avoid contact with water to prevent potentially violent
reaction or fire.


Ventilation:

Keep container in well-ventilated area.


Store away from heat.

Store out of direct sunlight.

Store away from acids.

Packaging of the substance and or preparation: polyethylene lined 5 liter steel drums

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: UN2810
Transport: Transportation occurs in closed and resistant containers
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None

Chemical reaction with water: silane hydrolysis

Dust explosion: Not applicable

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Not applicable

Industry - Possibility of neutralisation: Neutralisation, not specified (A630)

Industry - Possibility of destruction: controlled discharge: In the case of an accidental spillage, the substance is
absorbed by an absorbant material. This residue should be
considered as industrial chemicals waste and disposed of in
an incineration (A660) and preferably in second order
landfills (A650)

Industry - Possibility of destruction - incineration: In the case of an accidental spillage, the substance is
absorbed by an absorbant material. This residue should be
considered as industrial chemicals waste and disposed of in
an incineration (A660) and preferably in second order
landfills (A650)

Industry - Possibility of destruction - water purification: not applicable

Public at large - Possibility of recovery/recycling: Not applicable as the substance will not be available for
the public at large.

Public at large - Possibility of neutralisation: Not applicable as the substance will not be available for
the public at large.

Public at large - Possibility of destruction: controlled discharge: Not applicable as the substance will not be available for
the public at large.

Public at large - Possibility of destruction - incineration: Not applicable as the substance will not be available for
the public at large.

Public at large - Possibility of destruction - water purification: Not applicable as the substance will not be available for
the public at large.

Public at large - Possibility of destruction - others: Not applicable as the substance will not be available for