Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Reference substance name:
Red 0106-PP1
IUPAC Name:
Red 0106-PP1

Study design

Analytical method:
other: HPLC with UV/VIS-detection

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
2.7
Temp.:
20 °C
Remarks on result:
other: pH of the solutions analyzed not reported

Any other information on results incl. tables

Based on the calculation during the preliminary test, the log Pow of RED 0106-PP1 was estimated to above 2.1. Therefore the HPLC-method was chosen to conduct the main test. Six common standards, which have known log Pow values in the range of 1.6 to 5.7, were used as reference standards during the main test. The RED 0106-PP1 solution was injected three times and the combined reference item solution was injected six times. The log Pow was calculated using a regression curve (log k' vs. log Pow) and was found to be 2.7. The chromatography of the test item resulted in one sharp main peak with a well defined and reproducible retention time. The HPLC method was therefore considered to be suitable for the purpose of the study. Based on the chromatographic data, RED 0106-PP1 was considered to be stable during the test procedure.

Applicant's summary and conclusion

Conclusions:
Log Pow = 2.7