Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
471-140-1
EC Name:
-
Cas Number:
121240-56-0
Molecular formula:
C16H37F2P
IUPAC Name:
hydrogen tetrabutylphosphanium difluoride

Results and discussion

Flash point
Flash point:
> 110 °C
Atm. press.:
1 010 hPa

Any other information on results incl. tables

At 110°C the measurement was stopped in order to avoid possible damage to the equipment from corrosion.

Applicant's summary and conclusion