Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10.12.10-13.12.10
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU and OECD guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
no
Type of method:
capillary method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
>= 211 - <= 215 °C
Decomposition:
yes
Remarks:
evolving gas during further heating

Applicant's summary and conclusion

Conclusions:
The test item showed a melting point of 211-215°C